阀组装
Valve assembly
If the valve is damaged or worn out, it must be replaced immediately.
To replace the powder chamber valve:
Do not turn the powder chamber upside down.
Unscrew the valve assembly under the powder chamber with a coin, unclip the cap and extract the
valve.
Place the new valve in the correct position on the support and screw the assembly under the powder
chamber.
If an O-ring is damaged or worn out, it must be replaced immediately.
Valve assembly
FB-580_CN_rev_B_01_Not Util AIR-FLOW MASTER.indd 60 13.10.2017 10:00:20