Loading...
MVP D-TEK™ Operating Instructions 6
Document no. 10000104
Controls and Indicators
Front
Function
Indicator/Control
Description
Power
LED
Green T-1 Glows when power is applied
Detect
LED
Red T-1¾ Glows to indicated detection
Frequency Counter
Momentary Switch
Pull up towards Power LED and release
Reset
Momentary Switch
Push down towards Freq. and release
Frequency
Three position
Switch
Low, High, Medium. Unit must be reset after
any change
Sensitivity
BCD Switch
0,1,2,3,4,5,6,7,8,9 must be on a number
BACK
DIP Switch Functions
OFF
ON
1
Pulse on
Relay 2
Presence on
Relay 2
2
Pulse on
Detect
Pulse on
Un-detect
3
Constant
Presence
4 Minute limited
presence time
4
“Fail Secure”
“Fail Safe”
5
Filter OFF
Filter On
6
ASB OFF
Automatic
Sensitivity Boost
7
Extend Detect
6 seconds
8
Extend Detect
3 seconds
DIP 7 & 8 ON extend time is 9 seconds