Maintenance
9 Maintenance
Generators maintenance is described in this section. It may only be per-
formed by qualified specialist personnel.
Maintenance and repair which is neither described in this operating manual
nor in the possibly also delivered operating and maintenance instructions
may only be undertaken by authorized service personnel from the manu-
facturer.
9.1 Maintenance plan
Maintenance work on your generator must be performed periodically in or-
der to secure its readiness to use and reliability over a long period. This
work is only to be undertaken by trained specialist personnel. Contact your
dealer or our
service hotline at: +49 7123 9737-44
service@endress-stromerzeuger.de
NOTICE!
Please note that, in the case of a concluded warranty agreement, you will
lose all rights to make claims if your generator is not serviced according to
manufacturer regulations.
You can find an overview of the time plan and scope of the required maintenance
work in the following maintenance schedule.
Maintenance work Maintenance interval according to time
or operating hours [h]
Item Maintenance step Daily / 8
h
After 1
month /
20 h
every 3
months
or 50 h
annual-
ly every
100 h
Electrical safety Check X
Engine oil
Check fill level X
Change X
Air filter
Check X
Clean; replace if necessary X
Spark plug
Check the electrode gap,
clean; change when necessary
X
Valves Check; adjust if necessary X
Spark catcher Check; clean if necessary X
Tank and filter Cleaning X
Fastening and thread-
ed joints
X X
Maintenance work should be performed by your service partner.