46
Maintenance
3. Remove the securing clip from the spark screen.
4. Use a small slotted-head screwdriver to get the spark screen out of the ex-
haust gas outlet and then pull it out completely.
The spark screen is removed.
5. Assess the condition of the spark screen and replace it if it is damaged.
6. If the spark screen does not need replacing, clean it thoroughly with the aid
of the wire brush.
7. Perform steps 1 to 3 in reverse order in order to fasten the spark screen
again.
The spark screen is serviced. The generator can be put into operation again.
9.7 Cleaning the power generator
Keep your Generators clean and dry to ensure safe use at all times and a long
service life. Never expose your Generators to extreme weather conditions, envi-
ronments with heavy dust and dirt, moisture or aggressive vapours.
DANGER!
Danger of current flow if water enters.
Mortal danger from electrocution
Never clean the device during active operation.
Never clean the device under running water or by using a high pressure
cleaner.
NOTICE!
Never use a garden hose to clean the Generators. Water can get inside
through the cooling slots and damage the device.
Proceed as follows to clean the Generators:
Use a soft brush to remove any dirt or oil.
Use a damp cloth to clean the outside of the device
Inspect all ventilation and cooling slots to ensure that they are clean and free.
Use a clean cloth or an air compressor (pressure must not exceed 1.7 kPa /
bar) to thoroughly dry the device.