EasyManua.ls Logo

Endress+Hauser Liquicap M FMI51 - Zone 2 Application:

Endress+Hauser Liquicap M FMI51
28 pages
Go to English
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Liquicap M EG 05 022 / XA00346F-C
16 Endress+Hauser
Zone 2 Application:
Electronic
insert
Type of protection/
level of protection
Electrical data Ambient temperature
electronic
Temperature
class
Process
temperature
FEI50H II 3 G
Ex nA IIC
Ui 30 V
Ii 120 mA
Pi 1 W
Ci 2.4 nF
Li 0
–50 °C Ta +60 °C * T6
see the tempera-
ture diagram
on the next page
–50 °C Ta +70 °C * T3...T5
FEI57C II 3 G
Ex nA IIC
Ui 19.2 V
Ii 108 mA
Pi 1 W
Ci 2.4 nF
Li 0
–50 °C Ta +60 °C * T6
–50 °C Ta +70 °C * T3...T5
FEI55 II 3 G
Ex nA IIC
Ui 36 V
Ii 100 mA
Pi 1 W
Ci 2.4 nF
Li 0
–50 °C Ta +55 °C * T6
see the tempera-
ture diagram
on the next page
–50 °C Ta +70 °C * T3... T5
FEI57S II 3 G
Ex nA IIC
Ui 16.1 V
Ii 100 mA
Pi 1 W
Ci 2.4 nF
Li 0
–50 °C Ta +55 °C * T6
–50 °C Ta +70 °C * T3...T5
FEI58 II 3 G
Ex nA IIC
Ui 18 V
Ii 52 mA
Pi 170 mW
Ci 0
Li 0
–50 °C Ta +55 °C * T6
–50 °C Ta +70 °C * T3...T5
* for F16 housing: –40 °C…+55 °C, +60 °C and/or +70 °C
Electronic
insert
Type of protection/
level of protection
Power supply Relay circuit
FEI52
(3 wire PNP)
Ex nA IIC 10... 55 V DC
FEI54
(Relay)
Ex nC IIC 19...253 V AC 253 V AC / 6 A *
1500 VA / cos ϕ = 1
750 VA / cos ϕ > 0.7
19... 55 V DC 30 V DC / 6 A *
125 V DC / 0.2 A
* for T13 housing: 4 A