XA01810F-C Liquiphant FTL51B, FTL63
10 Endress+Hauser
ID Px, Rx (Accessory Enclosed)
Selected option Description
FTL51B
FTL63
PA
1)
Weather protection cover, 316L
PB
2)
Weather protection cover, plastic
R6
3)
Test magnet
1) Only in connection with Position 6 = M
2) Only in connection with Position 6 = B, C
3) Only in connection with Position 3, 4 = A8
Safety
instructions:
General
The device is intended to be used in explosive atmospheres as defined
in the scope of IEC 60079-0 or equivalent national standards. If no
potentially explosive atmospheres are present or if additional
protective measures have been taken: The device may be operated
according to the manufacturer's specifications.
Devices suitable for zone separation (marked Ga/Gb or Da/Db) are
always suitable for installation in the less critical zone (Gb or Db).
Due to space limitations the corresponding marking maybe not
indicated on the nameplate.
Staff must meet the following conditions for mounting, electrical
installation, commissioning and maintenance of the device:
Be suitably qualified for their role and the tasks they perform
Be trained in explosion protection
Be familiar with national regulations
Install the device according to the manufacturer's instructions and
national regulations.
Do not operate the device outside the specified electrical, thermal and
mechanical parameters.
Only use the device in media to which the wetted materials have
sufficient durability.
Avoid electrostatic charging:
Of plastic surfaces (e.g. enclosure, sensor element, special
varnishing, attached additional plates, ..)
Of isolated capacities (e.g. isolated metallic plates)
Refer to the temperature tables for the relationship between the
permitted ambient temperature for the sensor and/or transmitter,
depending on the range of application and the temperature class.
Alterations to the device can affect the explosion protection and must
be carried out by staff authorized to perform such work by
Endress+Hauser.
Safety
instructions:
Special conditions
Permitted ambient temperature range at the electronics enclosure:
–40 °C ≤ T
a
≤ +70 °C