XA01810F-C Liquiphant FTL51B, FTL63
22 Endress+Hauser
Connection data
Optional specification, ID Nx, Ox = NF, NG
When using the Bluetooth® module: No changes to the connection
values.
Associated intrinsically safe power supply unit with max. electrical
specifications below the characteristic values of the electronic inserts
Basic specification,
Position 3, 4
Power supply circuit
A7 U
i
= 14.6 V
I
i
= 100 mA
P
i
= 633 mW
L
i
= 0
C
i
= 3 nF
A8 U
i
= 16 V
I
i
= 52 mA
P
i
= 170 mW
L
i
= 0
C
i
= 30 nF
Only associated intrinsically safe power supply unit FML621 from
Endress+Hauser
Basic specification,
Position 3, 4
Power supply circuit
GA U
i
= 27.6 V
I
i
= 93 mA
P
i
= 640 mW
L
i
= 3 µH
C
i
= 3 nF
Cable entry parameters
Ex ia IIC
Not relevant.