Important document information Micropilot FMR51, FMR52 FOUNDATION Fieldbus
10 Endress+Hauser
Feature
010
Approval Available for Feature 020 "Power Supply; Output"
A
1)
B
2)
C
3)
E
4)
/G
5)
K
6)
/L
7)
I3 IECEx: Ex d [ia] IIC T6-T1 Ga/Gb
IEXEx: Ex ta IIIC Txx°C Da/Db
FMR51
FMR52
XA00684F XA00684F XA00684F XA00692F XA00684F
I4 IECEx: Ex ia IIC T6-T1 Ga/Gb
IECEx: Ex d [ia] IIC T6-T1 Ga/Gb
FMR51
FMR52
XA00681F XA00681F XA00681F XA00689F -
KA KC Ex ia IIC T6 Ga FMR51
FMR52
XA01045F XA01045F XA01045F XA01047F -
KB KC Ex ia IIC T6 Ga/Gb FMR51
FMR52
XA01045F XA01045F XA01045F XA01047F -
KC KC Ex d[ia] IIC T6 FMR51
FMR52
XA01046F XA01046F XA01046F XA01048F XA01046F
MA INMETRO: Ex ia IIC T6 Ga FMR51
FMR52
XA01286F XA01287F XA01288F XA01296F -
MC INMETRO: Ex d[ia] IIC T6 Ga/Gb FMR51
FMR52
XA01292F XA01292F XA01293F XA01298F XA01294F
MH INMETRO: Ex ic IIC T6 Gc FMR51
FMR52
XA01289F XA01290F XA01291F XA01297F -
NA NEPSI Ex ia IIC T6 Ga FMR51
FMR52
XA01199F XA01199F XA01199F XA01208F -
NB NEPSI Ex ia IIC T6 Ga/Gb FMR51
FMR52
XA01199F XA01199F XA01199F XA01208F -
NC NEPSI Ex d[ia] IIC T6 Ga/Gb FMR51
FMR52
XA01202F XA01202F XA01202F XA01211F XA01202F
NG NEPSI Ex nA II T6 Gc FMR51
FMR52
XA01201F XA01201F XA01201F XA01210F XA01201F
NH NEPSI Ex ic IIC T6 Gc FMR51
FMR52
XA01201F XA01201F XA01201F XA01210F XA01201F
N2 NEPSI Ex ia IIC T6 Ga/Gb, Ex iaD 20/21 T85…
90oC
FMR51
FMR52
XA01205F XA01205F XA01205F XA01214F -
N3 NEPSI Ex d[ia] IIC T6 Ga/Gb, DIP A20/21
T85…90oC IP66
FMR51
FMR52
XA01206F XA01206F XA01206F XA01215F XA01206F
8A FM/CSA IS+XP Cl.I,II,III Div.1 Gr.A-G FMR51
FMR52
XA01112F
XA01113F
XA01116F
XA01117F
XA01112F
XA01113F
XA01116F
XA01117F
XA01112F
XA01113F
XA01116F
XA01117F
XA01114F
XA01115F
XA01118F
XA01119F
-
1) 2-wire; 4-20mA HART
2) 2-wire; 4-20mA HART, switch output
3) 2-wire; 4-20mA HART, 4-20mA
4) 2-wire; FOUNDATION Fieldbus, switch output
5) 2-wire; PROFIBUS PA, switch output
6) 4-wire 90-253VAC; 4-20mA HART
7) 4-wire 10.4-48VDC; 4-20mA HART
For certified devices the relevant Safety Instructions (XA) are indicated on the
nameplate.