Proline Prowirl F 200 PROFIBUS PA Commissioning
Endress+Hauser 109
Parameter overview with brief description
Parameter Prerequisite Description Selection / User
entry
Factory setting
Operating mode Define the output as a pulse,
frequency or switch output.
Pulse
Frequency
Switch
Pulse
Assign frequency output The Frequency option is
selected in the Operating
mode parameter (→  106).
Select process variable for
frequency output.
Off
Volume flow
Corrected volume
flow
Mass flow
Flow velocity
Temperature
Calculated
saturated steam
pressure
*
Steam quality
*
Total mass flow
*
Energy flow
*
Heat flow
difference
*
Off
Mass flow unit Select mass flow unit.
Effect
The selected unit applies for:
Output
Low flow cut off
Simulation process variable
Unit choose list Country-specific:
kg/h
lb/min
Volume flow unit Select volume flow unit.
Effect
The selected unit applies for:
Output
Low flow cut off
Simulation process variable
Unit choose list Country-specific:
m³/h
ft³/min
Corrected volume flow unit Select corrected volume flow
unit.
Effect
The selected unit applies for:
Corrected volume flow
Unit choose list Country-specific:
Nm³/h
Sft³/h
Energy flow unit For the following order code:
"Sensor version", option "Mass
flow"
Select energy flow unit.
Result
The selected unit applies for:
Outputs
Low flow cut off
Unit choose list Country-specific:
kW
Btu/h
Pressure unit For the following order code:
"Sensor version", option "Mass
flow"
Select process pressure unit.
Effect
The unit is taken from the:
Calculated saturated steam
pressure
Atmospheric pressure
Maximum value
Fixed process pressure
Pressure
Reference pressure
Unit choose list Country-specific:
bar
psi
Velocity unit Select velocity unit.
Result
The selected unit applies for:
Flow velocity
Maximum value
Unit choose list Country-specific:
m/s
ft/s

Table of Contents