EasyManua.ls Logo

Endress+Hauser Proline Promag W 400 - User Manual

Endress+Hauser Proline Promag W 400
186 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Products Solutions Services
Operating Instructions
Proline Promag W 400
EtherNet/IP
Electromagnetic flowmeter
BA01214D/06/EN/03.15
71280372
Valid as of version
01.00.zz (Device firmware)
AUTHORIZED DISTRIBUTOR:
InstrumentsAndControl.com
Houston, Texas USA
sales@InstrumentsAndControl.com
832-615-3588

Table of Contents

Other manuals for Endress+Hauser Proline Promag W 400

Questions and Answers

  • J
    Jennifer FernandezNov 26, 2025
    How to connect to the Web server of Endress+Hauser Proline Promag W 400 Measuring Instruments?
    • M
      Melissa MayNov 26, 2025
      If you're having trouble connecting to the Web server of your Endress+Hauser Measuring Instruments: 1. Verify the settings for the Ethernet interface of your computer, referring to ? ? 64. Consult with your IT manager to check the network settings. 2. Using the "FieldCare" operating tool, check whether the Web server of the measuring device is enabled and enable it if necessary ? ? 67. 3. Disable the use of the proxy server in your web browser settings. For example, in MS Internet Explorer: go to Control Panel, open Internet Options, select the Connections tab, double-click LAN settings, and disable the use of the proxy server. 4. Ensure no other network connections or programs are active on your computer. If using a docking station for notebooks, ensure that a network connection to a...
  • R
    Richard HensleyAug 25, 2025
    What to do if my Endress+Hauser Measuring Instruments display shows 'Communication Error'?
    • J
      Jeffrey GlennAug 26, 2025
      If you see a "Communication Error" and "Check Electronics" message on the local display of your Endress+Hauser Measuring Instruments, it indicates that communication between the display module and the electronics has been interrupted. Check the cable and the connector between the main electronics module and the display module. If the issue persists, consider ordering spare part ? ? 124.
  • M
    Melissa ReevesAug 27, 2025
    Why does my Endress+Hauser Proline Promag W 400 Measuring Instruments show correct value but signal output is incorrect?
    • J
      Jennifer GarciaAug 27, 2025
      If your Endress+Hauser Measuring Instruments show the correct value on the local display but the signal output is incorrect (though within the valid range), it is likely due to a configuration error. Check and correct the parameter configuration.
  • R
    Robin FordAug 28, 2025
    What causes signal output outside the valid range in Endress+Hauser Proline Promag W 400?
    • D
      david29Aug 28, 2025
      If the signal output of your Endress+Hauser Measuring Instruments is outside the valid range, the main electronics module might be defective. Consider ordering spare part ? ? 124.
  • J
    Joanne McdonaldAug 29, 2025
    What to do if Endress+Hauser Proline Promag W 400 Web browser is frozen?
    • P
      Pamela ScottAug 30, 2025
      If your web browser freezes and you can no longer operate your Endress+Hauser Measuring Instruments, it could be due to: * Active data transfer: Wait until the data transfer or current action is finished. * Lost connection: Check the cable connection and power supply. Refresh the web browser, and restart it if necessary.
  • R
    Renee RobinsonSep 16, 2025
    What to do if Web browser is frozen while using Endress+Hauser Measuring Instruments?
    • L
      Lydia FisherSep 16, 2025
      If you're experiencing a frozen Web browser while operating your Endress+Hauser Measuring Instruments and operation is no longer possible, it could be due to: * Data transfer being active. Wait until the data transfer or current action is finished. * A lost connection. Check the cable connection and power supply. Then, refresh the Web browser and restart if necessary.
  • H
    hartchristianSep 13, 2025
    Why is the backlighting of the local display red on my Endress+Hauser Measuring Instruments?
    • W
      William WhiteSep 14, 2025
      If the backlighting of the local display on your Endress+Hauser Measuring Instruments is red, this indicates that a diagnostic event with an "Alarm" diagnostic behavior has occurred. Take remedial measures.
  • T
    Thomas McdonaldSep 15, 2025
    How to change the language on Endress+Hauser Measuring Instruments display?
    • J
      Jared BlackburnSep 15, 2025
      If the text on the local display of your Endress+Hauser Measuring Instruments appears in a foreign language and cannot be understood, the operating language is likely configured incorrectly. To fix this: 1. Press the indicated buttons for 2 seconds to return to the "home position." 2. Press the indicated button. 3. Set the desired language in the Language parameter.
  • D
    dana72Sep 6, 2025
    What causes no or incomplete display of contents in the Web browser for Endress+Hauser Proline Promag W 400 Measuring Instruments?
    • D
      dillonkaylaSep 7, 2025
      If you experience no or incomplete display of contents in the web browser while using your Endress+Hauser Measuring Instruments, it may be because JavaScript is not enabled or cannot be enabled. Enable JavaScript. Also, enter http://192.168.1.212/ basic.html as the IP address.
  • A
    Amber PetersenSep 4, 2025
    How to change the language on Endress+Hauser Proline Promag W 400 Measuring Instruments local display?
    • K
      Kim NelsonSep 4, 2025
      If the text on the local display of your Endress+Hauser Measuring Instruments appears in a foreign language that you cannot understand, it's likely that the incorrect operating language is configured. To change it: 1. Press ? + ? for 2 seconds (to reach the "home position"). 2. Press ?. 3. Set the desired language in the Language parameter.

Summary

Basic Safety Instructions

Personnel Requirements

Defines the necessary qualifications and authorizations for personnel involved with the device.

Workplace and Operational Safety

Covers safety measures for workplace environment and device operation, including hazard warnings.

Incoming Acceptance and Product Identification

Installation

Installation Conditions

Covers mounting position, environmental requirements, and special installation needs.

Mounting the Measuring Device

Provides step-by-step instructions for mounting the sensor and transmitter.

Post-Installation Check

A checklist to verify correct installation and device readiness.

Electrical Connection

Connection Conditions

Details requirements for connecting cables, terminals, and supply units.

Connecting the Measuring Device

Step-by-step instructions for connecting the remote version and transmitter.

Post-Connection Check

A checklist to verify the correctness of electrical connections.

Operation Options

Accessing Operating Menu via Local Display

Details interaction with the device using its local display interface.

Web Browser Access

Describes how to operate and configure the device using a web browser.

System Integration

Commissioning

Device Address Configuration

Steps to configure the device's IP address via software.

Measuring Device Configuration

Guides through configuring device parameters like tag name and units.

Settings Protection

Methods to protect device settings from unauthorized changes.

Operation

Ethernet Settings Management

Instructions for reading and modifying current Ethernet settings like IP address.

Reading Measured Values

How to view process variables and totalizer values via the device menu.

Diagnostics and Troubleshooting

General Troubleshooting

Common problems with local display and output signals, with solutions.

Local Display Diagnostics

Information on diagnostic messages, status signals, and remedial measures on the local display.

Web Browser Diagnostics

How to view diagnostic information and remedy steps via the web interface.

Repair

Technical Data

Input Specifications

Lists the measured and calculated variables the device can process.

Appendix

Endress+Hauser Proline Promag W 400 Specifications

General IconGeneral
Measurement PrincipleElectromagnetic
Housing MaterialAluminum, Stainless steel
Device TypeFlowmeter
Nominal DiameterDN 15 to DN 400
LiningPTFE
Electrode Material316L stainless steel
Pressure RangeUp to 40 bar (depending on nominal diameter)
Output Signal4 to 20 mA
Power Supply24 V DC
Degree of ProtectionIP67
Accuracy±0.2% of the measured value