Device Type | Electromagnetic Flowmeter |
---|---|
Housing Material | Aluminum, stainless steel |
Measuring Principle | Electromagnetic induction |
Measuring Range | 0.1 m/s to 10 m/s |
Process Pressure | Up to 40 bar (depending on nominal diameter) |
Output Signal | 4-20 mA HART, Pulse, Frequency, Alarm |
Power Supply | 24 V DC |
Degree of Protection | IP67 |
Lining Material | PTFE |
Electrode Material | Stainless Steel |
Material | Stainless Steel |
Communication | HART |
Nominal Diameter | DN 15 to 600 (½ to 24") |
Details on suitable applications and media for the flowmeter.
Explanation of the Faraday's law of induction used for flow measurement.
Overview of transmitter and sensor versions and their specifications.
Current, pulse/frequency outputs for Promag 50 transmitter.
Current, pulse/frequency outputs for Promag 53 transmitter.
Diagrams for electrical connections and power supply specifications.
Mapping of inputs/outputs to terminal numbers for Promag 50 and 53.
Requirements for supply voltage and potential equalisation.
Instructions for grounding metal pipes to prevent interference.
Reference conditions, maximum error, and repeatability specifications.
Permissible medium temperature based on tube lining.
Information on Ex approvals, CE, communication protocol certifications, and standards.
Selection codes for configuring Promag 50P and 53P flowmeters.