Proline Promag 50P, 53P
Endress+Hauser 35
Fitted electrodes Measuring, reference and EPD electrodes
Standard available with 1.4435/316L SS, Alloy C-22, tantalum, platinum/rhodium 80/20
Optional: measuring electrodes made of platinum/rhodium 80/20
Process connection Flange connection:
EN 1092-1 (DIN 2501), < DN 350 From A, > DN 300 From B
(dimensions acc. to DIN 2501; DN 65 PN 16 and DN 600 PN 16 exclusively to EN 10921)
•ANSI B16.5
JIS B2238
AS2129 Table E
AS4087 Cl. 14
Surface roughness PFA liner: 16 µin ( 0.4 µm)
•Electrodes:
1.4435/316L SS, Alloy C-22: 12 to 10 µin (0.3 to 0.5 µm)
Tantalum, platinum/rhodium: 12 to 10 µin (0.3 to 0.5 µm)
(all data relate to parts in contact with the medium)
Human interface
Display elements Liquid-crystal display: backlit, two lines (Promag 50) or four lines (Promag 53) with 16 characters per line
Custom configurations for presenting different measured-value and status variables
•Totalizer:
Promag 50: 2 totalizers (7-digit plus 7-digit overflow with sign and units)
Promag 53: 3 totalizers (7-digit plus 7-digit overflow with sign and units)
Operating elements Unified operation concept for both types of transmitter:
Promag 50:
Local operation with three push buttons (–, +, E)
Quick Setup menus for straightforward commissioning
Promag 53:
Local operation with Touch Control (–, +, E)
Application-specific Quick Setup menus for straightforward commissioning
Language group Language groups available for operation in different countries:
Promag 50, Promag 53:
Western Europe and America (WEA):
English, German, Spanish, Italian, French, Dutch and Portuguese
Eastern Europe and Scandinavia (EES):
English, Russian, Polish, Norwegian, Finnish, Swedish and Czech
South and east Asia (SEA):
English, Japanese, Indonesian
Promag 53:
China (CIN):
English, Chinese
You can change the language group via the operating program “ToF Tool - Fieldtool Package.”
Remote operation Promag 50: Remote control via HART, PROFIBUS DP/PA
Promag 53: Remote control via HART, PROFIBUS DP/PA, MODUBUS RS485, FOUNDATION Fieldbus