8

Table of Contents

Other manuals for Endress+Hauser Proline Promag 55

Questions and Answers

  • K
    Kristina RamosAug 2, 2025
    What to do if there is an incorrect connection to the PROFIBUS master on Endress+Hauser Switch?
    • S
      Savannah SmithAug 2, 2025
      If there's an incorrect connection to the PROFIBUS master, verify the supply voltage at Terminals 1/2. Check the device fuse (2 A slow-blow / 250 V for 20 to 260 V AC and 20 to 64 V DC). For PROFIBUS PA, check the data line at Terminal 26 = PA + and Terminal 27 = PA -. For PROFIBUS DP, check the data line at Terminal 26 = B (RxD/TxD-P) and Terminal 27 = A (RxD/TxD-N).
  • R
    Ryan MckenzieAug 10, 2025
    What to do if no display is visible and no output signals are present on Endress+Hauser Switch?
    • T
      Timothy BrownAug 11, 2025
      If there is no display and no output signals, first check the supply voltage at Terminals 1 and 2. Then, check the device fuse (2 A slow-blow / 250 V for 20 to 260 V AC and 20 to 64 V DC). If these are okay, the measuring electronics may be defective, and you should order spare parts.
  • J
    jennifercarrollAug 16, 2025
    What to do if no display is visible, but output signals are present on Endress+Hauser Switch?
    • A
      Alicia FreemanAug 17, 2025
      If the display is not visible but output signals are present, check if the ribbon-cable connector of the display module is correctly plugged into the amplifier board. If it is correctly plugged, the display module or measuring electronics may be defective, and you should order spare parts.
  • M
    moodyannaAug 25, 2025
    How to change the language of display texts on Endress+Hauser Switch?
    • S
      Sarah RoseAug 25, 2025
      To change the language, switch off the power supply. Then, press the OS keys simultaneously while switching the device back on. The display text will appear in English (default) and is displayed at maximum contrast. If this does not work, the measuring electronics may be defective, and you should order spare parts.

Summary

Safety instructions

Designated use

Specifies the intended purpose and limitations for the measuring device.

Installation, commissioning, operation

Outlines procedures for installation, setup, and operation by trained personnel.

Operational safety

Details safety considerations for device operation and hazardous environments.

Installation

Installation conditions

Specifies environmental and site requirements for optimal device installation.

Mounting location

Recommends suitable and unsuitable locations for mounting the sensor to ensure accuracy.

Installation

Provides step-by-step instructions for installing the sensor and transmitter components.

Installing the Promag S sensor

Detailed instructions for installing the Promag S sensor, including seal considerations.

Installing the Promag H sensor

Detailed instructions for installing the Promag H sensor, including process connections.

Post-installation check

Checklist to perform after installation to ensure correct setup and operation.

Wiring

Connecting the measuring unit

Details terminal assignments for connecting the measuring unit to power and fieldbus.

Connecting the transmitter

Procedure for connecting the transmitter to power supply and fieldbus cables.

PROFIBUS DP connection diagram

Illustrates the wiring diagram for connecting PROFIBUS DP devices.

PROFIBUS PA connection diagram

Illustrates the wiring diagram for connecting PROFIBUS PA devices.

Post-connection check

Checklist to verify correct wiring and connections after installation.

Operation

Error messages

Details the types and presentation of system and process errors.

Hardware PROFIBUS DP settings

Configures hardware settings for PROFIBUS DP communication on the device.

PROFIBUS PA hardware settings

Configures hardware settings for PROFIBUS PA communication on the device.

Configuring the write protection

Instructions on using jumpers to enable or disable hardware write protection for parameters.

Configuring the device address

Details methods for setting the PROFIBUS PA device address via local operation or switches.

Commissioning

Function check

Ensures all final checks are completed before starting up the measuring point.

Quick Setup

Guides through essential parameters for standard operation and additional functions.

Quick Setup Commissioning

Step-by-step guide for initial device setup and configuration.

Quick Setup Communication

Guides on configuring PROFIBUS communication settings for data transfer.

Configuration

Details advanced configuration options for specific measuring tasks and functions.

Commissioning the PROFIBUS interface

Provides instructions for commissioning the PROFIBUS DP/PA interface.

PROFIBUS DP commissioning

Step-by-step guide for commissioning the PROFIBUS DP interface.

PROFIBUS PA commissioning

Step-by-step guide for commissioning the PROFIBUS PA interface.

PROFIBUS DP;PA system integration

Guides on integrating the device into a PROFIBUS DP/PA network.

Device master file (GSD file)

Explains the necessity and types of GSD files for PROFIBUS network configuration.

PROFIBUS DP cyclic data transmission

Describes cyclic data transmission for PROFIBUS DP using the Promag 55 GSD file.

PROFIBUS PA cyclic data transmission

Describes cyclic data transmission for PROFIBUS PA using the Promag 55 GSD file.

Modules for cyclic data transmission

Details the individual modules used for cyclic data transmission in PROFIBUS PA.

Adjustment

Describes adjustment procedures necessary for accurate flow measurement.

Empty-pipe;full-pipe adjustment

Guides on performing EPD adjustment for accurate flow measurement in partially filled pipes.

Troubleshooting

Troubleshooting instructions

Provides a systematic checklist for diagnosing and resolving faults during operation.

System error messages

Details system errors, their indications, and diagnostic information.

List of system error messages

Provides a comprehensive list of system error codes, causes, and remedies.

Process error messages

Details process errors, their indications, and diagnostic information.

List of process error messages

Provides a comprehensive list of process error codes, causes, and remedies.

Technical data

Technical data at a glance

Provides a summary of key technical specifications for quick reference.

Power supply

Provides information on electrical connections, supply voltage, and power consumption.

Measuring accuracy

Details the standard measuring accuracy for volume flow and conductivity.

Endress+Hauser Proline Promag 55 Specifications