Technical data Proline Promag 55 PROFIBUS DP/PA
150 Endress+Hauser
10.1.10 Mechanical construction
Design / dimensions The dimensions and face-to-face length of the sensor and transmitter can be found in the separate
"Technical Information" for each device which can be downloaded in PDF format from
www.endress.com. A list of the available "Technical information" documents can be found in the
"Supplementary documentation" section ä 156.
Weight (SI units) Promag S
!
Note!
The following weights apply to standard pressure ratings and without packaging material.
Nominal
diameter
Weight in kilograms [kg]
Compact version Remote version (without cable)
Sensor Transmitter
[mm] EN (DIN) / AS* JIS EN (DIN) / AS* JIS (Wall-mount housing)
15
PN 40
6.5
10K
6.5
PN 40
4.5
10K
4.5 6.0
25 7.3 7.3 5.3 5.3 6.0
32 8.0 7.3 6.0 5.3 6.0
40 9.4 8.3 7.4 6.3 6.0
50 10.6 9.3 8.6 7.3 6.0
65
PN 16
12.0 11.1
PN 16
10.0 9.1 6.0
80 14.0 12.5 12.0 10.5 6.0
100 16.0 14.7 14.0 12.7 6.0
125 21.5 21.0 19.5 19.0 6.0
150 25.5 24.5 23.5 22.5 6.0
200
PN 10
45 41.9
PN 10
43 39.9 6.0
250 65 69.4 63 67.4 6.0
300 70 72.3 68 70.3 6.0
350 115 113 6.0
400 135 133 6.0
450 175 173 6.0
500 175 173 6.0
600 235 233 6.0
Transmitter (compact version): 3.4 kg
High-temperature version: +1.5 kg
* Only DN 25 and 50 are available for flanges according to AS