Technical data Proline Promag 55 PROFIBUS DP/PA
154 Endress+Hauser
Process connections Promag S
Flange connection:
• EN 1092-1 (DIN 2501)
– DN < 300 (12"): form A
– DN > 300 (12"): form B
– DN 65 (2½") PN 16 and DN 600 (24") PN 16 exclusively according to EN 1092-1
•ANSI
• JIS
•AS
Promag H
With O-ring:
• Welding nozzle DIN (EN), ISO 1127, ODT/SMS
• Flange EN (DIN), ANSI, JIS
• Flange made of PVDF EN (DIN), ANSI, JIS
•External thread
• Internal thread
• Hose connection
• PVC adhesive fitting
With molded seal:
• Welding nozzle DIN 11850, ODT/SMS
• Clamp ISO 2852, DIN 32676, L14 AM7
• Coupling DIN 11851, DIN 11864-1, ISO 2853, SMS 1145
• Flange DIN 11864-2
Surface roughness • Lining with PFA: 0.4 μm (16 μin)
• Electrodes: 0.3 to 0.5 μm (12 to 20 μin)
• Process connection made of stainless steel: 0.8 μm (31 μin)
All data relate to wetted parts.
10.1.11 Human interface
Display elements • Liquid crystal display: illuminated, four lines with 16 characters per line
• Custom configurations for presenting different measured values and status variables
• 3 totalizers
• At ambient temperatures below –20 °C (–4 °F), the readability of the display may be impaired.
Operating elements • Onsite operation with three optical sensor keys (S/O/F)
• Application-specific Quick Setup menus for straightforward commissioning
Language groups Language groups available for operation in different countries:
• Western Europe and America (WEA):
English, German, Spanish, Italian, French, Dutch and Portuguese
• Eastern Europe/Scandinavia (EES):
English, Russian, Polish, Norwegian, Finnish, Swedish and Czech.
• South and East Asia (SEA):
English, Japanese, Indonesian
•China (CN):
English, Chinese
!
Note!
You can change the language group via the operating program "FieldCare".