Troubleshooting Proline Promag 55 PROFIBUS DP/PA
136 Endress+Hauser
9.6.2 PROFIBUS PA
A0004780
Fig. 67: Spare parts for PROFIBUS PA transmitters (field and wall-mount housing)
1 Power unit board (20 to 260 V AC, 20 to 64 V DC)
2 Amplifier board
3 I/O board (COM module), permanent assignment
4 S-DAT (sensor data storage device)
5 T-DAT (transmitter data storage device)
6 F-CHIP (function chip for optional software)
7 Display module
8 Fieldbus connector consisting of protection cap, connector, adapter PG 13.5/M20.5
(only for PROFIBUS-PA, order No. 50098037)