Technical data Proline Promag W 400 EtherNet/IP
138 Endress+Hauser
Sensor
• As standard: IP66/67, type 4X enclosure
• Optionally available for remote version:
– IP66/67, type 4X enclosure; fully welded, with protective varnish EN ISO 12944 C5-M.
Suitable for use in corrosive atmospheres.
– IP68, type 6P enclosure; fully welded, with protective varnish as per EN ISO 12944 C5-
M. Suitable for permanent immersion in water ≤3 m (10 ft) or 48 hours at depths ≤
10 m (30 ft).
– IP68, type 6P enclosure; fully welded, with protective varnish as per EN ISO 12944
Im1/Im2/Im3. Suitable for permanent immersion in saline water ≤3 m (10 ft) or 48
hours at depths ≤10 m (30 ft) or in buried applications.
Shock resistance Compact version
6 ms 30 g, according to IEC 60068-2-27
Remote version
• Transmitter: 6 ms 30 g, according to IEC 60068-2-27
• Sensor: 6 ms 50 g, according to IEC 60068-2-27
Vibration resistance Compact version
• Vibration sinusoidal, 1 g peak, according to IEC 60068-2-6
• Vibration broad-band random, 1.54 g rms, according to IEC 60068-2-64
Remote version
• Transmitter
– Vibration sinusoidal, 1 g peak, according to IEC 60068-2-6
– Vibration broad-band random, 1.54 g rms, according to IEC 60068-2-64
• Sensor:
– Vibration sinusoidal, 2 g peak, according to IEC 60068-2-6
– Vibration broad-band random, 2.70 g rms, according to IEC 60068-2-64
Mechanical load • Protect the transmitter housing against mechanical effects, such as shock or impact; the
use of the remote version is sometimes preferable.
• Never use the transmitter housing as a ladder or climbing aid.
Electromagnetic
compatibility (EMC)
• As per IEC/EN 61326 and NAMUR Recommendation 21 (NE 21)
• Complies with emission limits for industry as per EN 55011 (Class A)
For details refer to the Declaration of Conformity.
16.9 Process
Medium temperature range • 0 to +80 °C (+32 to +176 °F) for hard rubber, DN 50 to 2000 (2 to 78")
• –20 to +50 °C (–4 to +122 °F) for polyurethane, DN 25 to 1200 (1 to 48")
In custody transfer mode, the permitted fluid temperature is
0 to +50 °C (+32 to +122 °F).
Conductivity ≥ 5 μS/cm for liquids in general
Note that in the case of the remote version, the requisite minimum conductivity also
depends on the cable length .