Proline Promag W 400 EtherNet/IP Technical data
Endress+Hauser 137
Flat Spec flow values0.2 %
Nominal diameter v
0.2
[mm] [in] [m/s] [ft/s]
25 to 600 1 to 24 1.5 4.92
Electrical conductivity
Max. measured error not specified.
Repeatability o.r. = of reading
Volume flow
max. ±0.1 % o.r. ± 0.5 mm/s (0.02 in/s)
Electrical conductivity
Max. ±5 % o.r.
16.7 Installation
"Mounting requirements" → 19
16.8 Environment
Ambient temperature
range
→ 21
Storage temperature The storage temperature corresponds to the operating temperature range of the
measuring transmitter and the appropriate measuring sensors.
• Protect the measuring device against direct sunlight during storage in order to avoid
unacceptably high surface temperatures.
• Select a storage location where moisture cannot collect in the measuring device as
fungus or bacteria infestation can damage the liner.
• If protection caps or protective covers are mounted these should never be removed
before installing the measuring device.
Atmosphere If a plastic transmitter housing is permanently exposed to certain steam and air mixtures,
this can damage the housing.
If you are unsure, please contact your Endress+Hauser Sales Center for clarification.
Degree of protection Transmitter
• As standard: IP66/67, type 4X enclosure
• When housing is open: IP20, type 1 enclosure