Proline Promag W 400 EtherNet/IP Operation options
Endress+Hauser 65
2. If a 2nd network card is not used: all the applications on the notebook should be
closed, or all the applications that require the Internet or network, such as e-mail,
SAP applications, Internet or Windows Explorer, i.e. close all open Internet browsers.
3. Configure the properties of the Internet protocol (TCP/IP) as defined in the table
above.
Starting the Web browser
1. Start the Web browser on the computer.
2. If the IP address of the measuring device is known, enter the defined device address
in the address line of the Web browser. If it is unknown, read the IP address via local
operation ("Diagnostics" menu → Device information → IP address) or set the upper
DIP switch No. 2 to ON, restart the device and enter the standard IP address
192.168.1.212 → 64.
The login page appears.
Device tag
Webserv.language
English
Ent. access code
Access stat.tool Maintenance
21
OK
Device name
3
A0017362
1 Device tag
2 Picture of device
If a login page does not appear, or if the page is incomplete → 106
8.4.4 Logging on
1. Select the preferred operating language for the Web browser.
2. Enter the access code.
3. Press OK to confirm your entry.
Access code 0000 (factory setting); can be changed by customer
If no action is performed for 10 minutes, the Web browser automatically returns to
the login page.