Technical data Proline Promag W 400 EtherNet/IP
156 Endress+Hauser
Process connections • EN 1092-1 (DIN 2501)
3)
– DN ≤ 300: fixed flange (PN 10/16/25/40) = form A
– DN ≥ 350: fixed flange (PN 6/10/16/25) = flat face
– DN 450 to 2000
4)
: fixed flange (PN 6/10/16) = flat face
• ASME B16.5
– DN 25 to 600 (1 to 24"): fixed flange (Class 150)
– DN 350 to 2000 (14 to 78")
4)
: fixed flange (Class 150)
– DN 25 to 150 (1 to 6"): fixed flange (Class 300)
• AWWA C207
– DN 48 to 72": fixed flange (Class D)
– DN 48 to 78"
4)
: fixed flange (Class D)
• AS 2129
– DN 50 to 1200: fixed flange (Table E)
– DN 350 to 1200
4)
: fixed flange (Table E)
• AS 4087
– DN 50 to 1200): fixed flange (PN 16)
– DN 350 to 1200
4)
: fixed flange (PN 16)
• JIS B2220
– DN 50 to 300: fixed flange (10K)
– DN 25 to 300: fixed flange (20K)
For information on the materials of the process connections → 154
Surface roughness Electrodes with 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022); tantalum:
≤ 0.3 to 0.5 µm (11.8 to 19.7 µin)
(All data relate to parts in contact with fluid)
16.11 Operability
Local operation Via display module
A0020538
Display elements
• 4-line display
• White background lighting; switches to red in event of device errors
• Format for displaying measured variables and status variables can be individually
configured
• Permitted ambient temperature for the display: –20 to +50 °C (–4 to +122 °F)
The readability of the display may be impaired at temperatures outside the temperature
range.
3) Dimensions as per DIN 2501, DN 65 (2 ½") PN 16 and DN 600 (24") PN 16 only as per EN 1092-1
4) Order code for "Design", option A "Insertion length short"