EasyManua.ls Logo

Endress+Hauser Proline Promag W 400 User Manual

Endress+Hauser Proline Promag W 400
186 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Products Solutions Services
Operating Instructions
Proline Promag W 400
EtherNet/IP
Electromagnetic flowmeter
BA01214D/06/EN/03.15
71280372
Valid as of version
01.00.zz (Device firmware)
AUTHORIZED DISTRIBUTOR:
InstrumentsAndControl.com
Houston, Texas USA
sales@InstrumentsAndControl.com
832-615-3588

Table of Contents

Other manuals for Endress+Hauser Proline Promag W 400

Questions and Answers:

Endress+Hauser Proline Promag W 400 Specifications

General IconGeneral
Measurement PrincipleElectromagnetic
Housing MaterialAluminum, Stainless steel
Device TypeFlowmeter
Nominal DiameterDN 15 to DN 400
LiningPTFE
Electrode Material316L stainless steel
Pressure RangeUp to 40 bar (depending on nominal diameter)
Output Signal4 to 20 mA
Power Supply24 V DC
Degree of ProtectionIP67
Accuracy±0.2% of the measured value

Summary

Basic Safety Instructions

Personnel Requirements

Defines the necessary qualifications and authorizations for personnel involved with the device.

Workplace and Operational Safety

Covers safety measures for workplace environment and device operation, including hazard warnings.

Incoming Acceptance and Product Identification

Installation

Installation Conditions

Covers mounting position, environmental requirements, and special installation needs.

Mounting the Measuring Device

Provides step-by-step instructions for mounting the sensor and transmitter.

Post-Installation Check

A checklist to verify correct installation and device readiness.

Electrical Connection

Connection Conditions

Details requirements for connecting cables, terminals, and supply units.

Connecting the Measuring Device

Step-by-step instructions for connecting the remote version and transmitter.

Post-Connection Check

A checklist to verify the correctness of electrical connections.

Operation Options

Accessing Operating Menu via Local Display

Details interaction with the device using its local display interface.

Web Browser Access

Describes how to operate and configure the device using a web browser.

System Integration

Commissioning

Device Address Configuration

Steps to configure the device's IP address via software.

Measuring Device Configuration

Guides through configuring device parameters like tag name and units.

Settings Protection

Methods to protect device settings from unauthorized changes.

Operation

Ethernet Settings Management

Instructions for reading and modifying current Ethernet settings like IP address.

Reading Measured Values

How to view process variables and totalizer values via the device menu.

Diagnostics and Troubleshooting

General Troubleshooting

Common problems with local display and output signals, with solutions.

Local Display Diagnostics

Information on diagnostic messages, status signals, and remedial measures on the local display.

Web Browser Diagnostics

How to view diagnostic information and remedy steps via the web interface.

Repair

Technical Data

Input Specifications

Lists the measured and calculated variables the device can process.

Appendix

Related product manuals