Operating Instructions
Proline Promass F 500
Modbus RS485
Coriolis flowmeter
K
e
e
p
c
o
v
e
r
h
t
i
g
t
w
h
i
l
e
S
p
a
n
n
u
n
g
ö
f
f
n
e
n
N
i
c
h
t
u
n
t
e
r
c
i
r
c
u
i
t
s
a
r
e
a
l
i
v
e
BA01540D/06/EN/01.16
71303227
Valid as of version
01.00.zz (Device firmware)

Table of Contents

Questions and Answers

  • B
    Brooke YoungAug 19, 2025
    What to do if local display is dark but signal output is within the valid range for Endress+Hauser Measuring Instruments?
    • M
      Matthew CruzAug 19, 2025
      If the local display is dark but the signal output of your Endress+Hauser Measuring Instruments remains within the valid range, it could be due to the display settings being too bright or too dark. Try adjusting the display by simultaneously pressing the indicated buttons to make it brighter or darker. Also, ensure the display module cable is correctly plugged into the main electronics module and display module. If the problem persists, the display module might be defective and require replacement.
  • E
    Edward MunozAug 21, 2025
    How to fix a dark local display with no output signals on Endress+Hauser Proline Promass F 500 Measuring Instruments?
    • A
      April ThompsonAug 21, 2025
      If the local display of your Endress+Hauser Measuring Instruments is dark and there are no output signals, several issues could be the cause. First, ensure that the supply voltage matches the value indicated on the nameplate and that the polarity is correct. Check all cable connections to the terminals, ensuring they are properly connected. Verify that the terminals are correctly plugged into both the I/O electronics module and the main electronics module. Also, inspect the connector between the main electronics module and the display module. If all connections are secure and the issue persists, the I/O or main electronics module may be defective and require a spare part.
  • A
    Amy FlemingAug 25, 2025
    Why is my Endress+Hauser Proline Promass F 500 device measuring incorrectly?
    • C
      Christopher HowardAug 25, 2025
      If your Endress+Hauser Measuring Instruments device measures incorrectly, it could be due to a configuration error or because the device is being operated outside of its intended application. Start by checking and correcting the parameter configuration. Also, make sure to observe the limit values specified in the "Technical Data."
  • G
    George TurnerAug 26, 2025
    How to fix not connecting to Web server on Endress+Hauser Proline Promass F 500 Measuring Instruments?
    • J
      Jonathan DavisAug 26, 2025
      If you are unable to connect to the web server of your Endress+Hauser Measuring Instruments, first check if the web server is enabled using "FieldCare" or "DeviceCare" operating tool, and enable it if necessary. Verify the Ethernet interface settings on your computer, including the Internet protocol (TCP/IP) properties, and consult with your IT manager to check the network settings. Ensure that your WLAN access data is correct, the WLAN network status is active, and WLAN is enabled on both the measuring device and operating device. Also, check for a WLAN network availability and ensure the network connection is stable. If needed, consider using an external WLAN antenna to improve network performance.
  • D
    Danielle GreeneAug 28, 2025
    How to change the language on Endress+Hauser Measuring Instruments display?
    • H
      Heather Oconnor DDSAug 28, 2025
      If the text on the local display of your Endress+Hauser Measuring Instruments appears in a foreign language that you cannot understand, it is likely that the incorrect operating language is configured. To change this, first press the indicated buttons for 2 seconds to reach the "home position". Then, navigate to the Display language parameter and set the desired language.
  • T
    Thomas CurtisAug 30, 2025
    How to fix content of Web browser incomplete or difficult to read on Endress+Hauser Proline Promass F 500?
    • J
      James MaddenAug 30, 2025
      If the content in your web browser is incomplete or difficult to read when accessing your Endress+Hauser Measuring Instruments, it may be due to using a non-optimum version of the web server. Ensure you are using the correct web browser version. Clear the web browser cache and restart the web browser. Also, consider adjusting the font size or display ratio of the web browser to improve readability.
  • K
    Kristin MurphySep 1, 2025
    What to do if I see 'Communication Error' 'Check Electronics' on my Endress+Hauser Proline Promass F 500 Measuring Instruments?
    • K
      Karen WilliamsSep 1, 2025
      If you are experiencing a communication error on your Endress+Hauser Measuring Instruments, indicated by the message "Communication Error" "Check Electronics" on the local display, it suggests that the communication between the display module and the electronics is interrupted. Check the cable and the connector between the main electronics module and display module. If the issue persists, consider ordering a spare part.
  • B
    bakercodySep 3, 2025
    Why is there no write access to parameters on my Endress+Hauser Proline Promass F 500?
    • S
      Stephen HessSep 3, 2025
      If you are unable to write to parameters on your Endress+Hauser Measuring Instruments, it could be due to hardware write protection being enabled. Set the write protection switch on the main electronics module to the Off position. Alternatively, the current user role may have limited access authorization. Check the user role and enter the correct customer-specific access code.
  • M
    Marisa ShieldsSep 5, 2025
    What causes an incorrect signal output on Endress+Hauser Measuring Instruments when the local display is correct?
    • A
      Adam SanchezSep 5, 2025
      If the device shows the correct value on the local display, but the signal output is incorrect (though within the valid range) for your Endress+Hauser Measuring Instruments, this is likely due to a configuration error. You should check and correct the parameter configuration.
  • G
    greenewesleySep 8, 2025
    What to do if Web browser frozen and operation no longer possible on Endress+Hauser Measuring Instruments?
    • N
      Nathan AshleySep 8, 2025
      If the web browser freezes and operation is no longer possible when using your Endress+Hauser Measuring Instruments, it could be because data transfer is active. Wait until the data transfer or current action is finished. Alternatively, the connection may have been lost. Check the cable connection and power supply, then refresh the web browser and restart if necessary.

Summary

Document Information

Document Function

Explains the purpose and scope of these Operating Instructions.

Symbols Used

Details various symbols used throughout the document for safety, electrical, communication, etc.

Documentation

Describes the standard and supplementary technical documentation available for the device.

Registered Trademarks

Lists registered trademarks of Endress+Hauser and other companies.

Basic Safety Instructions

Requirements for Personnel

Outlines qualifications and authorization for personnel working with the device.

Designated Use

Specifies the intended application and media for the measuring device and warns against incorrect use.

Workplace Safety

Provides safety instructions for working on and with the device, including welding and wet conditions.

Operational Safety

Covers safe operation, conversions, and repair guidelines for the device.

Product Safety

States that the device is designed to meet state-of-the-art safety requirements.

IT Security

Covers warranty conditions and security mechanisms for device settings and data transfer.

Device-Specific IT Security

Details functions to support protective measures, including hardware write protection and passwords.

Product Description

Product Design

Describes the two available transmitter versions and their key components.

Incoming Acceptance and Product Identification

Incoming Acceptance

Outlines the steps for checking the device upon delivery, including order codes and damage.

Product Identification

Explains how to identify the measuring device using nameplates and order codes.

Transmitter Nameplate

Details the information provided on the transmitter nameplate with a diagram.

Sensor Nameplate

Details the information provided on the sensor nameplate with a diagram.

Symbols on Measuring Device

Explains symbols found on the measuring device, such as WARNING and protective ground.

Storage and Transport

Storage Conditions

Provides guidelines for storing the device to ensure protection and prevent damage.

Transporting the Product

Details instructions for safely transporting the measuring device to the installation point.

Packaging Disposal

Explains how to dispose of packaging materials, noting their recyclability.

Installation

Installation Conditions

States that no special supports are needed and external forces are absorbed by the device construction.

Mounting Position

Illustrates different mounting locations for the sensor and transmitter.

Requirements from Environment and Process

Covers ambient temperature ranges, system pressure, and thermal insulation requirements.

Special Mounting Instructions

Provides specific instructions for mounting, including rupture disk considerations.

Mounting the Measuring Device

Details the steps and tools required for mounting the transmitter and sensor.

Post-Installation Check

Lists checks to be performed after installation to ensure proper setup and function.

Electrical Connection

Connection Conditions

Outlines required tools and cable specifications for electrical connections.

Connecting the Measuring Device: Proline 500 - Digital

Provides step-by-step instructions for connecting the digital transmitter and sensor.

Connecting the Measuring Device: Proline 500

Details the process for connecting the sensor and transmitter for the Proline 500.

Ensure Potential Equalization

Explains requirements for potential equalization.

Special Connection Instructions

Offers connection examples for Modbus RS485 and other outputs.

Hardware Settings

Covers setting the device address and enabling the terminating resistor.

Ensuring the Degree of Protection

Details steps to guarantee the specified degree of protection after electrical connection.

Post-Connection Check

Lists checks to be performed after electrical connection.

Operation Options

Overview of Operation Options

Presents various methods for operating the device, including local, web, and software tools.

Structure and Function of the Operating Menu

Explains the organization and purpose of the device's operating menu.

Access to the Operating Menu via the Local Display

Details how to navigate and interact with the device using its local display.

Access to the Operating Menu via the Web Browser

Explains how to operate and configure the device using a web browser.

Access to the Operating Menu via the Operating Tool

Covers accessing the device's menu using tools like FieldCare and DeviceCare.

System Integration

Overview of Device Description Files

Provides information on device description file versions and how to acquire them.

Compatibility with Earlier Model

Discusses compatibility of Modbus registers with previous models.

Modbus RS485 Information

Details Modbus RS485 function codes, register information, and data maps.

Commissioning

Function Check

Emphasizes performing post-installation and post-connection checks before commissioning.

Setting the Operating Language

Explains how to set the device's operating language.

Configuring the Measuring Device

Guides the user through configuring the device via the Setup menu and wizards.

Advanced Settings

Calculated Values

Details parameters for calculating corrected volume flow and other fluid properties.

Carrying out a Sensor Adjustment

Covers parameters related to sensor functionality and adjustment.

Configuring the Totalizer

Explains how to configure the totalizer parameters for measuring cumulative values.

Carrying out Additional Display Configurations

Details how to configure the local display settings, including format and values.

WLAN Configuration

Guides through setting up the device's WLAN connection parameters.

Configuration Management

Explains how to save and restore device configurations.

Using Parameters for Device Administration

Covers parameters for managing device settings like access codes and resets.

Protecting Settings from Unauthorized Access

Write Protection via Access Code

Explains how to protect device configuration using user-specific access codes.

Write Protection via Write Protection Switch

Details how to lock the entire operating menu using a hardware switch.

Operation

Reading the Device Locking Status

Explains how to check the device's write protection status and locking options.

Adjusting the Operating Language

Provides information on configuring the device's display language.

Configuring the Display

Refers to sections for basic and advanced display configuration.

Reading Measured Values

Explains how to view current measured values for various process variables.

Adapting the Measuring Device to the Process Conditions

Covers basic and advanced settings for tailoring the device to process conditions.

Performing a Totalizer Reset

Details how to reset totalizers via the Operation submenu.

Showing Data Logging

Explains how to access and view logged measured values and trends.

Diagnostics and Troubleshooting

General Troubleshooting

Provides a table of common errors for the local display and their solutions.

Diagnostic Information via Light Emitting Diodes

Explains how transmitter and sensor LEDs indicate device status.

Diagnostic Information on Local Display

Describes how diagnostic messages and status signals are displayed on the local screen.

Diagnostic Information in the Web Browser

Explains how to view diagnostic information and remedy details via a web browser.

Diagnostic Information in DeviceCare or FieldCare

Covers accessing diagnostic information through DeviceCare or FieldCare software.

Diagnostic Information via Communication Interface

Details how to read diagnostic information using Modbus RS485 registers.

Adapting the Diagnostic Information

Explains how to configure diagnostic behavior and response modes.

Overview of Diagnostic Information

Provides a comprehensive list of diagnostic numbers, texts, and remedy instructions.

Pending Diagnostic Events

Describes how to view current and previous diagnostic events.

Diagnostic List

Explains how to view a list of pending diagnostic events and their priorities.

Event Logbook

Details how to view and filter chronological event messages.

Resetting the Measuring Device

Covers device reset options for configuration or defined states.

Device Information

Explains how to access device identification parameters like serial number and firmware version.

Firmware History

Lists firmware versions, release dates, and documentation codes.

Maintenance

Maintenance Tasks

States that no special maintenance work is required.

Exterior Cleaning

Provides guidelines for cleaning the device exterior.

Interior Cleaning

Offers points to observe for CIP and SIP cleaning procedures.

Measuring and Test Equipment

Mentions Endress+Hauser's range of test equipment and services.

Endress+Hauser Services

Highlights services offered for maintenance, recalibration, and device tests.

Repairs

General Notes

Outlines the repair and conversion concept, including modular design and spare parts.

Spare Parts

Explains how to identify and order spare parts using the W@M Device Viewer.

Endress+Hauser Services

Refers to sales centers for information on services like recalibration.

Return

Provides instructions and website for returning devices for repair or calibration.

Disposal

Covers procedures for removing and safely disposing of the measuring device.

Accessories

Device-Specific Accessories

Lists accessories specific to the transmitter, including cables and mounting kits.

Service-Specific Accessories

Details software and tools like Applicator, W@M, FieldCare, and DeviceCare.

System Components

Mentions system components like graphic display recorders and pressure transmitters.

Technical Data

Application

States the suitability of the device for flow measurement and media types.

Function and System Design

Explains the measuring principle and system structure (transmitter + sensor).

Input

Details measured variables and measuring ranges for liquids and gases.

Output

Lists output signals, current outputs, and pulse/frequency/switch outputs.

Power Supply

Specifies power supply options, terminal assignments, and power consumption.

Performance Characteristics

Covers error limits, accuracy, and repeatability under reference conditions.

Installation

Refers to "Mounting requirements" for installation details.

Environment

Details ambient temperature, storage temperature, climate class, and degree of protection.

Process

Covers medium temperature range, seals, density, and process connections.

Mechanical Construction

Provides information on design, dimensions, weight, and materials.

Operability

Lists supported languages and local operation methods.

Certificates and Approvals

Lists CE mark, C-Tick, Ex approval, sanitary compatibility, and Modbus certification.

Application Packages

Describes available packages to enhance device functionality.

Accessories

Refers to a list of available accessories for order.

Supplementary Documentation

Lists available documentation, including brief operating instructions and technical information.

Endress+Hauser Proline Promass F 500 Specifications

General IconGeneral
Device TypeCoriolis mass flowmeter
Measurement principleCoriolis
Transmitter housingAluminum or stainless steel
Housing MaterialAluminum or stainless steel
Protection ClassIP66/67
Measuring accuracy±0.1% of rate
Process pressureUp to 400 bar (up to 5800 psi)
DisplayGraphic display
Output4-20 mA HART
Power supply24 V DC
ApprovalsATEX, IECEx, FM, CSA
CommunicationHART, PROFIBUS DP
Wetted materialsStainless steel