Diagnostics and troubleshooting Proline Promass F 500 Modbus RS485
170 Endress+Hauser
In addition to the operation time of its occurrence, each event is also assigned a symbol
that indicates whether the event has occurred or is ended:
• Diagnostic event
– : Occurrence of the event
– : End of the event
• Information event
: Occurrence of the event
To call up the measures to rectify a diagnostic event:
• Via local display → 160
• Via Web browser → 161
• Via "FieldCare" operating tool → 162
• Via "DeviceCare" operating tool → 162
For filtering the displayed event messages → 170
12.11.2 Filtering the event logbook
Using the Filter options parameter you can define which category of event message is
displayed in the Events list submenu.
Navigation path
Diagnostics → Event logbook → Filter options
Filter categories
• All
• Failure (F)
• Function check (C)
• Out of specification (S)
• Maintenance required (M)
• Information (I)
12.11.3 Overview of information events
Unlike a diagnostic event, an information event is displayed in the event logbook only and
not in the diagnostic list.
Info number Info name
I1000 --------(Device ok)
I1079 Sensor changed
I1089 Power on
I1090 Configuration reset
I1091 Configuration changed
I1092 Embedded HistoROM deleted
I1111 Density adjust failure
I1137 Electronic changed
I1151 History reset
I1155 Reset electronic temperature
I1156 Memory error trend
I1157 Memory error event list
I1184 Display connected
I1209 Density adjustment ok
I1221 Zero point adjust failure
I1222 Zero point adjustment ok