EasyManua.ls Logo

Endress+Hauser Proline Promass I 300 User Manual

Endress+Hauser Proline Promass I 300
266 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Products Solutions Services
Operating Instructions
Proline Promass I 300
Coriolis flowmeter
PROFINET
K
e
e
p
c
o
v
e
r
h
t
i
g
t
w
h
i
l
e
S
p
a
n
n
u
n
g
ö
f
f
n
e
n
BA01741D/06/EN/04.21
71506078
2021-01-01
Valid as of version
01.01.zz (Device firmware)

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Endress+Hauser Proline Promass I 300 and is the answer not in the manual?

Endress+Hauser Proline Promass I 300 Specifications

General IconGeneral
Device TypeCoriolis mass flowmeter
Measuring PrincipleCoriolis
Accuracy±0.1% of rate
Process PressureUp to 100 bar
Output Signal4 to 20 mA
Power Supply24 V DC
Housing MaterialStainless steel
Approvals/CertificationsATEX, IECEx, FM
Protection ClassIP67
MaterialStainless steel
Process Temperature-50°C to +200°C

Summary

About this document

Symbols

Defines symbols used throughout the manual for clarity and safety.

Safety instructions

Requirements for the personnel

Outlines necessary qualifications and authorizations for personnel working with the device.

Designated use

Specifies the intended application and media for the measuring device.

Device-specific IT security

Details security functions to protect the device and its configuration from unauthorized access.

Protecting access via hardware write protection

Explains how a hardware switch disables write access to device parameters.

Protecting access via a password

Describes how to use passwords to secure device parameters and WLAN access.

Product description

Product design

Describes the physical components and overall structure of the measuring device.

Incoming acceptance and product identification

Product identification

Explains methods for identifying the device, including nameplates and order codes.

Transmitter nameplate

Details the information found on the transmitter's identification nameplate.

Sensor nameplate

Details the information found on the sensor's identification nameplate.

Storage and transport

Storage conditions

Provides guidelines for proper storage to maintain device integrity and prevent damage.

Transporting the product

Details the procedure for safely moving the device to its installation point.

Installation

Installation conditions

Specifies environmental and positional requirements for correct device installation.

Mounting the measuring device

Details the procedure and necessary tools for physically installing the measuring device.

Post-installation check

Outlines the essential checks to perform after the device has been installed.

Electrical connection

Connection conditions

Outlines requirements for cables, tools, and electrical safety during connection.

Connecting the measuring device

Provides step-by-step instructions for connecting the device to power and network interfaces.

Ensuring potential equalization

Explains the importance and procedure for potential equalization for measurement accuracy.

Hardware settings

Covers device configuration settings like naming and IP address activation.

Operation options

Access to the operating menu via the local display

Describes how to navigate and operate the device using its onboard display and controls.

Access to the operating menu via the Web browser

Details how to operate and configure the device remotely using a web browser interface.

Access to the operating menu via the operating tool

Explains how to operate the device using external software tools like FieldCare.

System integration

Device master file (GSD)

Explains the purpose and format of the GSD file for PROFINET system integration.

Cyclic data transmission

Details how the device exchanges data cyclically with an automation system.

Commissioning

Function check

Outlines the essential checks required before putting the device into operation.

Configuring the measuring device

Guides users through the setup menu for configuring device parameters for operation.

Advanced settings

Covers advanced configuration options including security, sensor adjustment, and display settings.

Protecting settings from unauthorized access

Explains methods like access codes and write protection switches to secure device configuration.

Operation

Reading measured values

Explains how to access and view the current process measurements displayed by the device.

Adapting the measuring device to the process conditions

Details how to adjust device settings for optimal performance under specific process conditions.

Performing a totalizer reset

Provides instructions for resetting the device's totalizer values to zero or a preset value.

Diagnostics and troubleshooting

General troubleshooting

Offers solutions for common issues encountered with the local display and output signals.

Diagnostic information on local display

Explains how diagnostic messages and status signals are presented on the device's local screen.

Calling up remedial measures

Guides users on how to access specific instructions for resolving diagnostic events.

Resetting the measuring device

Provides options for resetting the device configuration to factory or delivery settings.

Maintenance

Maintenance tasks

Outlines routine maintenance procedures, including cleaning and checks.

Repair

Notes for repair and conversion

Provides critical guidelines and requirements for performing device repairs and modifications.

Accessories

Device-specific accessories

Lists and describes accessories specifically designed for the transmitter and sensor components.

Communication-specific accessories

Details accessories that enable communication, such as field gateways and tablet PCs.

Technical data

Input

Lists available measured variables and specifies input signal types and ranges.

Output

Details the specifications for the device's various output signals, including current, pulse, and switch outputs.

Power supply

Provides detailed specifications for the device's power supply options, including terminal voltage and consumption.

Performance characteristics

Outlines key performance metrics like accuracy, repeatability, and temperature effects.

Process

Details process-related technical data, including medium temperature and pressure-temperature ratings.

Application packages

Describes optional software packages that enhance device functionality for specific applications.

Related product manuals