Proline Promass F 500 Modbus RS485 Installation
Endress+Hauser 33
Wall mounting
149 (5.85)
211 (8.31)
=
5.8 (0.23)
17 (0.67) =
14 (0.55)
5.8 (0.23)
A0029054
 12 Engineering unit mm (in)
1. Drill the holes.
2. Insert wall plugs into the drilled holes.
3. Screw in the securing screws slightly at first.
4. Fit the transmitter housing over the securing screws and mount in place.
5. Tighten the securing screws.
6.2.5 Mounting the transmitter housing: Proline 500
L
CAUTION
Ambient temperature too high!
Danger of electronics overheating and housing deformation.
Do not exceed the permitted maximum ambient temperature .
If operating outdoors: Avoid direct sunlight and exposure to weathering, particularly in
warm climatic regions.
L
CAUTION
Excessive force can damage the housing!
Avoid excessive mechanical stress.
The transmitter can be mounted in the following ways:
Post mounting
Wall mounting
Post mounting
L
WARNING
Order code for "Transmitter housing", option L "Cast, stainless": cast transmitters are
very heavy.
They are unstable if they are not mounted on a secure, fixed post.
Only mount the transmitter on a secure, fixed post on a stable surface.