Proline Promass F 500 Modbus RS485 Commissioning
Endress+Hauser 125
Parameter overview with brief description
Parameter Description Selection Factory setting
Installation direction Set sign of flow direction to match the
direction of the arrow on the sensor.
Flow in arrow direction
Flow against arrow direction
Flow in arrow direction
Zero point adjustment
All measuring devices are calibrated in accordance with state-of-the-art technology.
Calibration takes place under reference conditions →  190. Therefore, a zero point
adjustment in the field is generally not required.
Experience shows that zero point adjustment is advisable only in special cases:
To achieve maximum measuring accuracy even with low flow rates
Under extreme process or operating conditions (e.g. very high process temperatures or
very high-viscosity fluids).
Navigation
"Setup" menu → Advanced setup → Sensor adjustment → Zero point adjustment
Zero point adjustment
Zero point adjustment control
→  125
Progress
→  125
Parameter overview with brief description
Parameter Description Selection / User interface Factory setting
Zero point adjustment control Start zero point adjustment. Cancel
Busy
Zero point adjust failure
Start
Cancel
Progress Shows the progress of the process. 0 to 100 %
10.4.3 Configuring the totalizer
In the "Totalizer 1 to n" submenu the individual totalizer can be configured.
Navigation
"Setup" menu → Advanced setup → Totalizer 1 to n
Totalizer 1 to n
Assign process variable
→  126
Unit totalizer 1 to n
→  126
Totalizer operation mode
→  126
Failure mode
→  126