EasyManua.ls Logo

ENERAC 500 - Page 37

ENERAC 500
54 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
36
CALIBRATION COMMANDS
COMMAND FUNCTION
OFFS? ENERAC returns a list of voltage offsets for each sensor.
FACT? ENERAC returns a list of calibration factors for each sensor.
SPAN XX NNN ENERAC span calibrates sensor XX at a span value of NNN
PPM or percent. Be sure to feed the correct span gas and wait for
the sensor to stabilize before the analyzer receives this command,
as it will execute a span calibration immediately.
Span Range (NNN)
XX=CO Carbon Monoxide 10 2000
XX=NO Nitric Oxide 10 2000
XX=NO2 Nitrogen Dioxide 10 500
XX=SO2 Sulfur Dioxide 10 1000
XX=CMB Combustible Gases 0.1 5.0
XX=DFT Stack Draft (Inches
H
2
O)
-20 +20
XX=COIR NDIR Carbon
Monoxide
1.125 15.0
XX=CO2 NDIR Carbon Dioxide 9.0 20.0
XX=HC NDIR Hydrocarbons 450 20000
ZERO ENERAC will perform an autozero of all its sensors.
MASTER COMMANDS
COMMAND FUNCTION
LOGO? ENERAC returns its current model name (ENERAC M500).
HELP? ENERAC returns a list of all four-letter commands.
SRAL? ENERAC returns its serial number.
TURN OFF ENERAC powers down.
TURN ON ENERAC powers up. This command is not available via a
Bluetooth connection.
VERS? ENERAC returns its current firmware version.
VOLT? ENERAC returns a list of all system and sensor voltages