Operating Instructions
User ManUal
TST-D Battery Chargers
Users Manual 2013
www.energicplus.com
1

Questions and Answers

  • F
    floresjasminAug 13, 2025
    Why Energic Plus TST-D is not charging and display is off?
    • D
      Dean ParksAug 13, 2025
      The Energic Plus Battery Charger might not be reacting because the battery is not connected properly; check the battery connectors/harness. It could also be due to the charger being connected to the forklift motor connector; disconnect the forklift motor and connect the battery. Other potential causes include a blown output fuse (replace it and adjust AC input settings), reversed output cables (check charger, connectors, and battery polarities), a bad control board connection (check board connectors), or a faulty control board (replace it).
  • K
    Kendra WhiteAug 17, 2025
    What to do if Energic Plus TST-D smells hot?
    • P
      powelljaimeAug 17, 2025
      If your Energic Plus Battery Charger smells hot, it could be due to a bad location; install the charger in a proper location. Check for obstructed ventilation slots and remove any objects blocking them. Also, ensure the AC input settings are correct; adjust them to a higher voltage if necessary. Inspect and tighten all power wirings, and if the transformer is burned, replace it.
  • W
    wnelsonAug 20, 2025
    What to do if Energic Plus Battery Charger output current is too low?
    • M
      marymcdanielAug 20, 2025
      If the output current of your Energic Plus Battery Charger is too low, it could be due to wrong AC input settings; adjust the AC input settings to a lower voltage. Another reason may be that one AC phase is absent; check the AC input voltage on each phase. Also, inspect for blown diodes and replace the rectifier if needed. Finally, a bad contactor could be the cause; replace the contactor.
  • K
    kristinsnowAug 25, 2025
    What to do if Energic Plus Battery temperature is too high?
    • E
      Eric LucasAug 25, 2025
      If the battery temperature is too high when using the Energic Plus Battery Charger, adjust the AC input settings to a higher voltage. High battery power demand may also be the issue, so consider purchasing a battery with a bigger Ah. Insufficient cool down time before or after charging could be another factor; increase the cool down time. Lastly, check and replace the board or contactor if the automatic stop function isn't working.
  • K
    Kimberly RyanAug 27, 2025
    What to do if a message appears when battery is connected to Energic Plus Battery Charger?
    • C
      cnavarroAug 28, 2025
      If a message appears when the battery is connected to the Energic Plus Battery Charger, check the AC input voltage on each phase, AC input connections, and the AC disconnect switch and fuses, as the AC input may be absent. Alternatively, the contactor may be bad, requiring replacement of the contactor and freewheeling diode.
  • L
    Logan ChanAug 31, 2025
    Why is Energic Plus TST-D too noisy?
    • M
      michaelwareSep 1, 2025
      An Energic Plus Battery Charger might be too noisy due to a bad contactor. In this case, replace the contactor and freewheeling diode. Another possible cause is one or more shorted diodes, which would require replacing the rectifier.
  • E
    Eddie EdwardsSep 4, 2025
    What to do if Energic Plus Battery Charger output current is too high?
    • D
      Donald BatesSep 4, 2025
      If the output current from the Energic Plus Battery Charger is too high, adjust the AC input settings to a higher voltage. It is also possible that one or more cells are shorted, requiring you to repair the battery.
  • H
    hansonjohnSep 8, 2025
    What to do if Energic Plus Battery has low S.G. and doesn't last full shift?
    • J
      Juan SerranoSep 8, 2025
      If the battery has a low specific gravity or doesn't last a full shift when using the Energic Plus Battery Charger, adjust the AC input settings to a lower voltage. If this doesn't help, the battery capacity might be too low, and you may need to replace the battery.

Summary

Safety Instructions and Warnings

Electrical Shock Prevention

Guidelines to prevent electrical shock hazards, including grounding and damp area precautions.

Installation and Grounding

Procedures for proper installation and grounding of the charger.

Burn and Bodily Injury Prevention

Preventing burns from high currents and protection against battery acid.

Fire and Explosion Prevention

Measures to prevent fires and explosions caused by hydrogen gas.

Charger Installation

AC Voltage Selection

Grounding and Line Connection

How to Use the Charger

Battery Connection and Autostart

Charge Process

Charge Termination

Equalization Function

Maintenance Function

Trouble Shooting

Energic Plus TST-D Specifications

General IconGeneral
BrandEnergic Plus
ModelTST-D
CategoryBattery Charger
LanguageEnglish

Related product manuals