ENFORCER 365-Day Annual Timer
10 SECO-LARM U.S.A., Inc.
Programming (Continued)
Programming a PIN Code
If you forget the PIN Code, proceed as follows to unlock the timer and enter programming mode.
1. Turn off power to the timer and disconnect the backup battery.
2. Power up the timer and immediately press and hold the ENTER button for at least 3 seconds,
until the lock icon disappears from the display. This returns the PIN code to 0000.
3. Proceed with programming as usual.
Programming Relays in Tandem
Press ENTER to see the
following.
S e t T a n d em
>D i s a bl e <
Press ENTER to change
enable/disable, SEL to
accept and move to .
Keep pressing SEL to
cycle
through and correct errors or
to go to the return icon .
Press SEL until
>S e t T a n d em <
appears.
Keep pressing SEL to
cycle
through again or to go to the
return icon ..
Press ENTER at the to
return to the home screen.
Press ENTER to see the
following.
S e t P i n
>0 0 0 0 < D i sa b l e
Press ENTER to change
the
first digit (0~9), SEL to
accept and move to the next
.
Repeat for each digit.
Press
SEL
at the last digit to move
to the enable/disable.
Press ENTER to change
enable/disable, SEL to
accept and move to .
>0 0 0 0 < D i sa b l e
Press SEL until
>S e t P i n C od e <
appears.
Keep pressing SEL
to cycle
through again or go to the
icon to press ENTER to
return to the home screen.