R1 = O F F Pv = 1 2 . 0
R2 = O F F Bv = 1 2 . 5
Users and installers of this product are responsible for ensuring that the installation and configuration of this product com
plies with all national, state,
and local laws and codes. SECO-LARM will not be held responsible for the use of this product in violation of any current laws or codes.
California Proposition 65 Warning:
These products may contain chemicals which are known to the State of California to cause cancer and birth defects or other
reproductive harm. For more information, go to www.P65Warnings.ca.gov.
LARM product is warranted against defects in material and workmanship while used in normal service for
sale to the original customer. SECO-LARM’s obligation is limited to the repair or replacement of any defective part if the unit is returned, transportation prepa
SECO-LARM. This Warranty is void if damage is caused by or attributed to acts of God, physical o
r electrical misuse or abuse, neglect, repair or alteration, improper
or abnormal usage, or faulty installation, or if for any other reason SECO-
LARM determines that such equipment is not operating properly as a result of causes other
than defects in material and workmanship. The sole obligation of SECO-LARM and the purchaser’s
exclusive remedy, shall be limited to the replacement or repair
only, at SECO-LARM’s option. In no event shall SECO-LARM be liable for any special, collateral, incidental, or consequ
ential personal or property damage of any
kind to the purchaser or anyone else.
LARM policy is one of continual development and improvement. For that reason, SECO LARM reserves the right to change specific
without notice. SECO-LARM is also not responsible for misprints. All trademarks are the property of SECO-LARM U.S.A., Inc.
or their respective owners.
Copyright © 2023 SECO-LARM U.S.A., Inc. All rights reserved.
Smart Charging
The timer's smart charging feature controls charging so that the battery is only charged when
necessary to prolong the life of the battery and ensure that a battery is not overcharged.
When a backup battery is connected, the timer will automatically detect it and start charging if the
battery voltage is less than 11.5V. However, if a battery's voltage is too far below that level, the
timer will not charge the battery to avoid a potential unsafe condition.
Charging will stop when the battery voltage reaches 12.8V and will remain on standby until the
battery voltage again falls below 11.5V or after 2 weeks, whichever comes first.
Checking Power Input and Backup Battery Level
To check the power input and backup battery level, from the
home screen, press the ENTER button.
The power input voltage will be shown as Pv=xx.x where xx.x represents the current input voltage.
The current backup battery level will be shown as Bv=xx.x or Bv xx.x, where xx.x represents the
current battery voltage and indicates that the battery is currently being charged.
Troubleshooting
My backup battery is not
charging
• Ensure all battery connections are correct and tight.
• Press the ENTER button from the home screen to show the "power
input and battery level" screen to confirm that the battery is connected
but not charging.
• Note that the battery will stop charging when the battery reaches 12.9 V
and will not resume charging until the battery's voltage falls below 11.5V
or after 2 weeks, whichever comes first.
How can I test that a relay
is working?
• You can use the System Test (see pg. 11) to toggle each relay on and
off to test that the relay works properly.
I am unsure that my
device is receiving the
correct input voltage
• From the home screen, press the ENTER button to see both the input
voltage and the backup battery voltage.