ENFORCER 7-Day Timer
SECO-LARM U.S.A., Inc. 3
Specifications
Operating voltage 10~48 VDC / 12~24 VAC
Number of relays 2 Form C
Relay contact rating 10A@14VDC
Relay active current draw 110mA@12VDC ±10% (per channel)
Standby current draw 14mA@12VDC ±10%
Backup battery type 12VDC (supports lead-acid compatible battery, not included)
Battery charge Smart charge, 50mA max., when battery is ≥11.5V and ≤12.8V
Event capacity 60 per relay
Operating temperature -4°~167° F (-20°~75° C)
Dimensions 4
1
/
8
"x3"x1
5
/
16
" (105x76x33 mm)
Weight 5.6-oz (158g)
Installation
1. Find a location where the LCD display is visible, and the buttons accessible. Mark the location.
2. Connect the wires (see Overview, Terminal Layout Chart, pg. 2 and Basic Wiring, pg. 4).
3. Connect a 12~24 VAC or 10~48 VDC power supply to the power input terminals, 1 and 2.
4. Connect the 12VDC battery backup to the backup battery input terminals 3 (+) and 4 (–) if
desired (not included).
5. Connect the devices that are being controlled to the outputs of relays 1 and/or 2 as well as any
other devices being connected.
NOTE: To protect the relay, you must install a 1N4004 diode—with the cathode (striped
end , not included) wired toward the positive side—in parallel with the
power supply and as close to the lock as possible for DC powered locks unless your
lock has a diode built in. AC powered locks and electromagnetic locks require a
varistor/MOV (05D390K or similar, not included) wired in the same location if the lock
does not have one built in (all SECO-LARM electromagnetic locks have built-in
protection). Failure to use these as directed will void the warranty.
6. Close the case and mount the unit to the location marked above.