EasyManuals Logo

ENFORCER SK-1123-SPQ User Manual

ENFORCER SK-1123-SPQ
32 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #27 background imageLoading...
Page #27 background image
27
ENFORCER Vandal Resistant Access Control Keypads
SECO-LARM U.S.A., Inc.
Programming the Door-Propped-Open Warning and Delay Time:
If the keypad is connected to an optional magnetic contact or other door protection switch or
device, the keypad can be programmed to beep when a door has been propped open. This
prompts authorized users to close a door that was not closed properly or to investigate a door that
may have been deliberately propped open.
1. Door-propped-open warning OFF (default):
81 0 #
2. Door-propped-open warning ON:
81 ttt #
NOTE:
TTT
represents the delay time, which can be set from 1 to 999 seconds.
The delay time provides time for a door to close normally before triggering the
door-propped-open warning.
The door-propped-open beeping will stop when the open door is closed.