Quick Programming Guide:
This page is for installers looking to do a basic installation and programming of the keypad.
For more in-depth installation and programming instructions, see the Table of Contents on page 4.
Programming Tips:
• The master, super user, common user, visitor, duress, and user codes cannot
be the same.
• A ashing amber LED indicates the keypad is in standby mode. A solid amber LED indicates the
keypad is in programming mode.
• If the keypad is set for Auto Code Entry Mode, your user codes will need to be the same
number of digits as the master code (see page 24).
Programming Instructions:
Follow the instructions below if the following covers your needs:
• A new master code.
• A single 4-digit user code for all users, and no proximity cards.*
• One output to unlock a door.
• A 3-second delay time in opening the door after the output is activated.
1. Turn off the beeping before the 1-minute power-up period ends:
12 #
2. Enter Programming Mode:
0000 **
NOTE:
0000
is the default master code
3. Change the master code:
01 xxxx #
NOTE: xxxx
is the new master code.
4. Set the user code to operate output #1 (unlock the door):
10 2 000 xxxx #
NOTE:
000
chooses user ID #1 of 1,000 possible users (000~999).
XXXX
is the new user code for user ID #1.
5. Set the output #1 delay time (skip this step if the default value of 5 seconds is
acceptable):
51 3 #
NOTE:
3
sets the output #1 delay time for 3 seconds.
6. Exit programming mode:
**