ENFORCER Outdoor Stand-Alone Keypads
SECO-LARM U.S.A., Inc 11
6. Exit Programming Mode by pressing again.
4. Exit Programming Mode by pressing .
E. Setting the Output #1 Access Mode*
DEFAULT: User card OR user code.
1. Enter Programming Mode by entering the Master Code twice.
Either user card OR user code (DEFAULT)
3. Enter one of the following:
1. Enter a user ID number.
Each Output #1 user can be programmed to have a user code and a user card.*
4. To program the next user, repeat from step 1 in section A, B, or C.
5. Exit Programming Mode by pressing .
2. If the left LED is red, previous user data exists. Clear it by entering . The keypad will beep in
confirmation and the left LED will turn green.
3. Enter a new user code.
Note ā For all of the following programming functions, the keypad must be in Programming Mode. To enter
Programming Mode, enter the Master Code twice.
Note: Deleting all users is recommended before changing the access mode to user card with user
code. See page 14, Deleting All Users.
*SK-2323-SPQ and SK-1323-SPQ only.
D. Program the Master Card (SK-1323-SPQ and SK-2323-SPQ only)
In addition to a Master Code, a Master Card can also be programmed. Swiping a Master Card will give
direct access to Programming Mode.
1. Enter Programming Mode by entering the Master Code twice. (Default Master Code is 1234)
3. On the keypad, enter .
4. Swipe a proximity card (PR-K1S1A or similar). This card is now the Master Card.
5. Exit Programming Mode by pressing .
2. If the left LED is solid green and the right LED is flashing orange, a Master card is already
programmed. Clear it by entering . The keypad will beep in confirmation and the left LED
will start flashing green.
1. Enter a user ID number.
4. Return to Programming Mode by pressing .
3. Swipe a new user card.
5. To program the next user, repeat from step 1 in section A, B, or C.
2. If the left LED is red, previous user data exists. Clear it by entering . The keypad will beep in
confirmation and the left LED will turn green.