Page 19
710237A
&86720(57(50,1$/675,3&211(&7,216
See diagram on page 15.
TS1-FS1
Used to connect one side of the First Stage of a two Stage Pilot Switch.
Use a single pole, normally open, momentary type Switch. Connect the
First Stage of a TWO Stage pilot Switch between TS1-FS1 and
TS1-GND terminals.
TS1-GND
Used as the common connection point for most all of the other terminal
strip connections. There are six GND terminals provided on TS1.
TS1-FS3
Used to connect one side of a Single Stage Pilot. Connect a Single Stage
Pilot between TS1-FS3 and TS1-GND terminals. Use a single pole,
normally open, momentary type switch.
Used to connect one side of a two Stage Pilot. Connect the Second Stage
of a two Stage pilot to TS1-FS3 and TS1-GND terminals. Use a single
pole, normally open, momentary type switch.
When initiated via TS1-FS3 the weld control will begin from the schedule
that is displayed in the SCHEDULE Display.
TS1-FS7/SS1
Used to connect one side of the second Single Stage Pilot for DUAL
SCHEDULE operation. Connect a Single Stage Pilot between TS1-FS7
and TS1-GND terminals. Use a single pole, normally open, momentary
type switch.
When initiated via TS1-FS7/SS1 the weld control will begin from
SCHEDULE 10 .
Terminal TS1-FS7/SS1 can also function as an External Schedule Select.
Terminals TS1-FS7/SS1 and TS1-FS11/SS3 become External Schedule
Selects when programed via the EXTENDED FUNCTIONS [SS],
EXTERNAL [01]. Use a single pole normally open switch connected to
TS1-FS7/SS1 as shown by the sketch in section 7.5. This switch can now
be used, along with TS1-FS11/SS3 as pointers to one of 4 schedules.
TS1-FS3 is used to then initiate the schedule pointed to. See TABLE 1 in
next connection point TS1-FS11/SS3, (Page 20).
CAUTION
A JUMPER IS NOT REQUIRED ON TS1-FS1 TO TS1-GND WHEN A
TWO STAGE FOOT SWITCH IS NOT USED