Page 30
10.
Program the schedule for the part to be welded as recommended by the machine
manufacturer or to RWMA standards for the work to be performed. Place the work in
the machine and set the WELD/NO WELD switch (both on control panel and any
EXTERNAL WELD/NO WELD switches) to the WELD position. The machine is now
ready to weld.
11.
If no standards have been set, it is recommended to use a short weld count for initial
setup and welding. Weld count can be increased, welding transformer tap can be
increased, and the percent current can then be adjusted for the best weld. The most
efficient use of the control and welding machine will generally be made at the lowest
welding transformer tap, the highest percent current setting and the shortest weld count.
12.
For repeat operation, program CYCLE MODE (16) to a CODE [01], and program OFF
count to allow sufficient time to reposition the part for subsequent welds.