13 14
Or you can scan the bar code.
Step 3: Click confirm to finish Adding MI.
Step 2: Click Add, then enter the SN of Monitor, click OK to finish adding monitor. Click
“+” button behind the Monitor SN, then enter the SN of microinverter, click OK to
finish binding.
Option 3. Use Envertecportal to add MI
Step 1: Login www.envertecportal.com with the newly-registered account, go to”
Settings—Management”.
Please notice the symbols.
7.1
Energize the System
1. Turn on the switch or the circuit breaker at each microinverter AC branch.
2. Turn on the main AC circuit breaker in the distribution box. Your system will start to
produce power after 3 minutes.
3. Envertech microinverters begin to communicate through the power lines to Enver-
Bridge. The entire system will be detected within 10 minutes.
4. The voltage and frequency of EVT360 can be adjusted on the site. If adjustments are
required by your local utility company, installers can use EnverBridge to manage grid
parameters after all microinverters have been detected.
7.2
EVT360 Operation
The Envertech microinverter is powered on when there is sufficient DC voltage from
the PV module. The LED light of each microinverter will blink green to indicate normal
start-up operation approximately 1 minute after DC power is applied.
7. Debugging and Operating
Only qualified personnel may connect the Envertech microinverter to
the utility grid after receiving prior approval from the electricalutility
company.
!
WARNING
Ensure that all AC and DC wiring is correct. Ensure that none of the
AC and DC wires is twisted or damaged.
!
WARNING
Adhere to all the safety measures described throughout this manual. If the PV system
does not operate correctly, the following troubleshooting measures can be applied by
qualified personnel.
8. Troubleshooting and Maintenance
Do not attempt to repair the Envertech microinverter.It contains no
user-serviceable parts. If the microinverter fails, contact your direct
supplier or Envertech customer service to obtain an RMA (return
merchandise authorization) number and start the replacement
process.
!
WARNING