REV. 09/2020
C1
Battery use and maintenance
C
1.1 Battery charging
•The truck must be parked within a shady and ventilated room;
•Avoid the existence of any metal object in the surface of the storage battery;
•All the cable and plug connection parts should be inspected in terms of obvious damages before
charging;
•The charger to be connected or disconnected must be under the state of not connecting to the
circuit;
•The safety provisions related to the storage battery and the manufacturer of charging station must
be strictly abode by.
•Charging in non-charging area is prohibited;
•No modication of vehicles;
•Do not use irregular charging sockets;
•The net height of the charging area shall be higher than 5m, and the safe distance from other
areas shall be greater than 5m.
Charging environment:
1.1.2 Charging the battery with internal charger
Charge lithium battery through a built-in
charger
•Inspect whether relevant charging
requirements are satised according to
“1.1.1 precautions”;
•Park the truck securely as described chapter
B Section1.2.6;
•Open the upper cover if necessary;
•Connect the power plug (1) and have it
inserted into a proper power supply.
1.1.1 Precautions
Lithium battery must be charged above 0°C, as excessively low charging temperature is likely to
result in the short circuit of battery cell.
power plug
WPL201/EPL151