2) The following rules must be observed when modifying the value of the
parameter in user battery type(factory default value is the same as sealed
type):
A. Over Voltage Disconnect Voltage > Charging Limit Voltage Equalize
Charging Voltage Boost Charging Voltage Float Charging Voltage >
Boost Reconnect Charging Voltage.
B. Over Voltage Disconnect Voltage > Over Voltage Reconnect Voltage
C. Low Voltage Reconnect Voltage > Low Voltage Disconnect Voltage
Discharging Limit Voltage.
D. Under Voltage Warning Reconnect Voltage > Under Voltage Warning
Voltage ≥ Discharging Limit Voltage.
Boost Reconnect Charging voltage > Low Voltage Disconnect Voltage.
2)Lithium Battery Control Voltage Parameters
The parameters are in the 12V system at 25 ºC; please double the
values in the 24V system.
Battery type
Voltage parameter
LiFePO
4
(4S)
Li-NiCoMn
(3S)
User
Over Voltage Disconnect Voltage
15.6V
13.5V
917V
Charging Limit Voltage
14.6V
12.6V
917V
Over Voltage Reconnect Voltage
14.5V
12.5V
917V
Equalize Charging Voltage
14.5V
12.5V
917V
Boost Charging Voltage
14.5V
12.5V
917V
Float Charging Voltage
13.8V
12.2V
917V
Boost Reconnect Charging
13.2V
12.1V
917V