EasyManuals Logo

Epever Tracer4210A User Manual

Epever Tracer4210A
36 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #25 background imageLoading...
Page #25 background image
21
5 Technical Specifications
Electrical Parameters
Item
Tracer
1206A
Tracer
1210A
Tracer
2210A
Tracer
3210A
Tracer
4210A
Nominal system
voltage
12/24VDC Auto
Rated charge
current
10A
10A
20A
30A
40A
Rated discharge
current
10A
10A
20A
30A
40A
Battery voltage
range
9V32V
Max. PV V
OC
60V
100V
MPP Voltage range
V
BAT
+2V50V
V
BAT
+2V90V
Max. PV input
power
130W/12V
260W/24V
260W/12V
520W/24V
390W/12V
780W/24V
520W/12V
1040W/24V
Self-consumption
<20mA(12V) <16mA(24V)
Temperature
compensate
coefficient
-3mV/ºC/2V(Default)
Communication
RS485(RJ45 interface)
V
BAT
is Battery voltage.
V
oc
less than 60V.
V
oc
less than 100V.
Environmental Parameters
Environmental
Parameter
LCD temperature range
-20℃~+70
Ambient temperature range*
-25℃~+45
Storage temperature range
-35℃~+80
Humidity range
≤95% (N.C.)
Enclosure
IP30
* Please operate controller at permitted ambient temperature. If over
permissible range, please derate capacity in service.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Epever Tracer4210A and is the answer not in the manual?

Epever Tracer4210A Specifications

General IconGeneral
BrandEpever
ModelTracer4210A
CategoryController
LanguageEnglish

Related product manuals