Tracer-AN Series
——MPPT Solar Charge Controller
User Manual
Models:
Tracer1206AN/Tracer2206AN
Tracer1210AN/Tracer2210AN
Tracer3210AN/Tracer4210AN

Questions and Answers

  • M
    Mitchell BrownAug 16, 2025
    How to fix the Epever Tracer1210AN Controller charging LED indicator when it's off during the daytime with proper sunshine on the PV modules?
    • W
      William StokesAug 17, 2025
      If the charging LED indicator is off during the daytime when sunshine falls on PV modules properly, confirm that the PV and battery wire connections are correct and tight.
  • M
    michaeldanielsAug 19, 2025
    What to do if the Epever Controller load has no output and the load/fault icon blink?
    • G
      Garrett ChapmanAug 20, 2025
      If the load has no output and the load/fault icon is blinking on your Epever Controller, it indicates a load overload. Reduce the number of connected electrical devices, restart the controller, or wait for one night-day cycle (night time > 3 hours).
  • J
    Justin GalvanAug 22, 2025
    Why does the Epever Tracer1210AN Controller battery level show full, with the battery frame and fault icon blinking?
    • A
      Aaron DanielsAug 22, 2025
      If the battery level on your Epever Controller shows full, but the battery frame and fault icon are blinking, it signifies a battery over voltage. Check if the battery voltage exceeds the OVD (over voltage disconnect voltage) and disconnect the PV.
  • D
    Diana MarshAug 25, 2025
    What to do if there is a Load Short Circuit on the Epever Controller?
    • S
      Shannon JordanAug 26, 2025
      If there is a load short circuit, carefully check the load connections and clear the fault. Restart the Epever Controller and wait for one night-day cycle (night time > 3 hours).
  • E
    Eric GreenAug 28, 2025
    What does it mean when the Epever Controller battery level is empty, battery frame blinks, and fault icon blinks?
    • K
      Kayla LeAug 28, 2025
      When the battery level shows empty, the battery frame blinks, and the fault icon blinks on the Epever Controller, it indicates that the battery is overheating. The controller will automatically turn the system off. The controller will resume once the temperature declines below 55 ºC.
  • B
    Bill LaneAug 30, 2025
    Why is my Epever Controller not working even though the wire connections are correct?
    • J
      jessica51Aug 30, 2025
      If your Epever Controller is not working despite correct wiring, the battery voltage may be too low. Check the battery voltage; it needs to be at least 8V to activate the controller.
  • M
    Mary DouglasSep 2, 2025
    What to do if Epever Tracer1210AN shows overload?
    • M
      Maria ScottSep 2, 2025
      If your Epever Controller indicates an overload, reduce the number of connected electrical devices. Then, restart the controller or press the button to clear the fault.
  • M
    Melissa JohnsSep 5, 2025
    What to do if Epever Tracer1210AN Controller has load short-circuit?
    • W
      whitelorraineSep 5, 2025
      If the Epever Controller displays a load short-circuit, carefully check the load connections and clear the fault. Then, restart the controller or press the button to clear the faults.
  • A
    Alexis TurnerSep 7, 2025
    What to do if Epever Controller indicates battery over discharged?
    • J
      Joseph EspinozaSep 7, 2025
      If your Epever Controller indicates that the battery is over discharged, the load will recover when the battery voltage is restored to or above the LVR (low voltage reconnect voltage). In the meantime, use alternative methods to recharge the battery.
  • S
    Scott OwensSep 10, 2025
    How to fix PV array open-circuit on Epever Controller?
    • E
      eparksSep 12, 2025
      To address a PV array open-circuit issue with your Epever Controller, verify that the PV array connections are correct and securely tightened.

Summary

Safety Instructions

General Safety Information

General safety guidelines for installation and operation.

General Product Information

MPPT Technology Explained

Details on MPPT technology and its benefits.

Battery Charging Stages

Description of the 3-stage battery charging process.

Installation Guide

PV Array Requirements

Specifications and guidelines for PV array connections.

Controller Operation

Maintenance and Troubleshooting

Protections Overview

Summary of the controller's safety protection features.

Troubleshooting Guide

Common issues, faults, and their solutions.

Product Specifications

Epever Tracer1210AN Specifications

General IconGeneral
TypeMPPT
Rated Charge Current10A
Rated System Voltage12V/24V Auto
Max PV Input Voltage100V
Temperature Compensation-3mV/°C/2V(Default)
GroundingNegative Grounding
Discharge Circuit Voltage Drop≤0.15V
Max PV Input Power130W/12V, 260W/24V
CommunicationRS485
ProtectionOverload, Short circuit
Battery TypeSealed, Gel, Flooded
Operating Temperature-25°C to +50°C