EasyManua.ls Logo

Epever Tracer1206A - User Manual

Epever Tracer1206A
36 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Tracer- A Series
——MPPT Solar Charge Controller
User Manual
Models
Tracer1206A /Tracer1210A
Tracer2210A/Tracer3210A/Tracer4210A

Questions and Answers

  • R
    Rachel TaylorAug 11, 2025
    What to do if Epever Controller interface is blinking due to overload or short circuit?
    • M
      Matthew LewisAug 11, 2025
      If the Epever Controller interface is blinking because of an overload or short circuit, remove or reduce the load. Then, press the button; the controller will resume working after 3 seconds.
  • J
    johnsonjanetAug 17, 2025
    What happens if the Epever Controller interface is blinking because of low battery voltage disconnect?
    • A
      Amy TurnerAug 17, 2025
      If the Epever Controller interface is blinking due to a low battery voltage disconnect, the controller will automatically cut off the output. The LED indicator will return to green automatically once the battery is fully charged.
  • J
    Jesus PettyAug 23, 2025
    Why is the Epever Controller LCD off during the day when the PV modules are in sunshine?
    • W
      Wayne ObrienAug 23, 2025
      The LCD might be off because of PV array disconnection. Confirm that the PV and battery wire connections are correct and tight.
  • A
    Amber SuttonAug 28, 2025
    What to do if Epever Tracer1206A Controller wire connection is correct, but the LCD doesn't display anything?
    • A
      aparsonsAug 28, 2025
      If the Epever Controller's LCD isn't displaying anything despite correct wiring, it could be due to: 1. Battery voltage being lower than 9V. Please check the battery voltage. It needs at least 9V to activate the controller. 2. PV voltage being less than the battery voltage. Check that the PV input voltage is higher than the battery's.
  • M
    martinnathanSep 4, 2025
    What causes the Epever Tracer1206A Controller interface to blink, indicating the battery voltage is too high?
    • B
      Brian SummersSep 4, 2025
      The Epever Controller interface might blink if the battery voltage is higher than the over voltage disconnect voltage (OVD). Check if the battery voltage is too high, and disconnect the solar module.

Epever Tracer1206A Specifications

General IconGeneral
Rated Charge Current10A
Rated Load Current10A
Rated Voltage12V/24V Auto
Max. PV Open Circuit Voltage50V
PWM ControlYes
Temperature Compensation-3mV/°C/2V(default)
DisplayLCD
TypeSolar Charge Controller
Max. PV Input Power130W/12V, 260W/24V
Self-consumption<10mA
Operating Temperature-35°C to +55°C
Battery TypeSealed, Gel, Flooded
ProtectionOvercharge, Over-discharge, Short circuit