Note: The wire size is only for reference. If there is a long distance between the
PV array and the controller or between the controller and the battery, larger
wires can be used to reduce the voltage drop and improve performance.
2.4 Mounting
CAUTION: The controller requires at least 150mm of clearance
above and below for proper air flow. Ventilation is highly
recommended if mounted in an enclosure.
WARNING: Risk of explosion! Never install the controller in a
sealed enclose with flooded batteries! Do not install in a confined
area where battery gas can accumulate.
WARNING: Risk of electric shock!
Exercise caution when handling solar wiring. The solar PV array
can produce open-circuit voltages in excess of 100 V when in
sunlight. Pay more attention to it.
ATTENTION: Le contrôleur Tracer nécessite au moins un
espace libre de 150mm au dessus et en dessous pour une
circulation correcte de l'air. Une ventilation est hautement
recommandée en cas d'installation dans un boitier.
AVERTISSEMENT: Risque d’explosion ! N'installez jamais le
Tracer dans un boitier fermé avec des batteries noyées!
N'installez pas dans un espace confiné où des gaz de batterie
peuvent s'accumuler.
AVERTISSEMENT: Risque d'électrochoc!
Faites attention lors de la manipulation des connexions solaires.
La matrice PV solaire peut produire des tensions supérieures à
100V, à la lumière du soleil. Soyez particulièrement attentif à
cela.