Tracer-AN Series
——MPPT Solar Charge Controller
User Manual
Models:
Tracer1206AN/Tracer2206AN
Tracer1210AN/Tracer2210AN
Tracer3210AN/Tracer4210AN

Questions and Answers

  • C
    Cheyenne CopelandAug 17, 2025
    How to fix the Epever Tracer1206AN charging LED indicator when it's off during the daytime with proper sunshine on the PV modules?
    • O
      olsoncherylAug 17, 2025
      If the charging LED indicator is off during the daytime when sunshine falls on PV modules properly, confirm that the PV and battery wire connections are correct and tight.
  • B
    Brian DavidAug 20, 2025
    What to do if the Epever Tracer1206AN load has no output and the load/fault icon blink?
    • K
      katherinegarciaAug 20, 2025
      If the load has no output and the load/fault icon is blinking on your Epever Controller, it indicates a load overload. Reduce the number of connected electrical devices, restart the controller, or wait for one night-day cycle (night time > 3 hours).
  • J
    Jessica StevensonAug 22, 2025
    Why does the Epever Controller battery level show full, with the battery frame and fault icon blinking?
    • A
      Annette GibsonAug 22, 2025
      If the battery level on your Epever Controller shows full, but the battery frame and fault icon are blinking, it signifies a battery over voltage. Check if the battery voltage exceeds the OVD (over voltage disconnect voltage) and disconnect the PV.
  • J
    jmurrayAug 25, 2025
    What to do if there is a Load Short Circuit on the Epever Tracer1206AN Controller?
    • S
      stephanie93Aug 26, 2025
      If there is a load short circuit, carefully check the load connections and clear the fault. Restart the Epever Controller and wait for one night-day cycle (night time > 3 hours).
  • K
    Katherine HenryAug 28, 2025
    What does it mean when the Epever Tracer1206AN Controller battery level is empty, battery frame blinks, and fault icon blinks?
    • K
      Kevin EvansAug 28, 2025
      When the battery level shows empty, the battery frame blinks, and the fault icon blinks on the Epever Controller, it indicates that the battery is overheating. The controller will automatically turn the system off. The controller will resume once the temperature declines below 55 ºC.
  • L
    Luis AndersonAug 31, 2025
    Why is my Epever Tracer1206AN Controller not working even though the wire connections are correct?
    • B
      Brandon MorganAug 31, 2025
      If your Epever Controller is not working despite correct wiring, the battery voltage may be too low. Check the battery voltage; it needs to be at least 8V to activate the controller.
  • R
    rnealSep 2, 2025
    What to do if Epever Tracer1206AN shows overload?
    • C
      Cheryl ThomasSep 2, 2025
      If your Epever Controller indicates an overload, reduce the number of connected electrical devices. Then, restart the controller or press the button to clear the fault.
  • J
    Joseph HornSep 5, 2025
    What to do if Epever Controller has load short-circuit?
    • D
      Diana SchwartzSep 5, 2025
      If the Epever Controller displays a load short-circuit, carefully check the load connections and clear the fault. Then, restart the controller or press the button to clear the faults.
  • T
    Terry IngramSep 7, 2025
    What to do if Epever Controller indicates battery over discharged?
    • G
      Gregory DaltonSep 8, 2025
      If your Epever Controller indicates that the battery is over discharged, the load will recover when the battery voltage is restored to or above the LVR (low voltage reconnect voltage). In the meantime, use alternative methods to recharge the battery.
  • K
    katie86Sep 12, 2025
    How to fix PV array open-circuit on Epever Controller?
    • W
      wendyclarkSep 12, 2025
      To address a PV array open-circuit issue with your Epever Controller, verify that the PV array connections are correct and securely tightened.

Summary

Important Safety Instructions

General Safety Information

General safety guidelines for installation and operation of the MPPT controller.

2. Installation Instructions

2.1 General Installation Notes

Important precautions and general guidance for the installation process.

2.4 Mounting

Provides guidelines for mounting the controller, including clearance and ventilation.

3. Operation

3.3 Setting Parameters

Covers setting parameters like battery type, voltage control, user settings, and load modes.

4. Protections, Troubleshooting and Maintenance

4.1 Protection Mechanisms

Details the controller's protection features against various electrical faults.

4.2 Troubleshooting Common Faults

Provides solutions for common problems, faults, and error indications.

4.3 Maintenance Procedures

Outlines recommended periodic maintenance tasks for optimal performance.

5. Technical Specifications

Electrical Parameters

Lists electrical specifications for all Tracer AN series controller models.

Epever Tracer1206AN Specifications

General IconGeneral
ModelTracer1206AN
TypeMPPT Solar Charge Controller
Rated Charge Current10A
Rated Load Current10A
Max. PV Input Power130W (12V system) / 260W (24V system)
Battery TypeSealed, Gel, Flooded, User
MPPT Tracking Efficiency99%
Max. Conversion Efficiency98%
Efficiency98%
Temperature Compensation-3mV/°C/2V(Default)
Altitude≤3000m
CoolingNatural Cooling
PV Input Voltage12V
Charge AlgorithmPWM
ProtectionShort circuit
Operating Temperature-20°C to +50°C
Storage Temperature-30°C to +70°C
GroundingNegative ground