Safety and operating instructions
© Construction Tools GmbH | 3390 5201 01 | 2023-05-15
Original Instructions
41
7.4.2 Manual lubrication
n
Make sure that the chisel is pressed down on a sur-
face up to the stop to prevent chisel paste from get-
ting onto the striking surface.
n
Only use chisel paste for lubrication.
n
Put the manual grease gun on the grease nipple and
inject chisel paste.
Lubrication interval: approx. every 2 hours
5 to 15 strokes from the manual grease gun
7.4.3 Chisel paste filling device
Construction Tools GmbH offers a device for refilling
empty cartridges. This can be mounted on a 15-kg or 45-
kg hobbock to fill empty cartridges as required.
Bio chisel paste
550-g Bio chisel paste cartridges packed per 12 car-
tridges:
part number 3363 1223 56
15-kg Bio chisel paste container,
part number 3363 1223 57
45-kg Bio chisel paste container,
part number 3363 1223 58
Chisel paste
500-g chisel paste cartridges packed per 12 cartridges:
part number 3363 0912 00
15-kg chisel paste container,
part number 3362 2639 00
45-kg chisel paste container,
part number 3362 2632 75
Manual grease gun for cartridges:
part number 3363 0345 67
Filling device for use with 15-kg containers:
part number 3363 0946 69
Filling device for use with 45-kg containers:
part number 3363 0664 11
For further information, please contact the Epiroc Cus-
tomer Center / Dealer in your area.