EPSON Stylus Photo R340/350 Revision A
Disassembly and Assembly Disassembly 47
Illustration (2)
Figure 2-9. Removing the Panel Board/LCD Module (2)
8. Release the four tabs ( ) that secure the Panel Board and remove it.
9. Remove the all buttons from the Housing Panel Assy.
10. Remove the two screws ( ) that secure the LCD Module.
11. Release the LCD Module from the two tabs ( ) by pulling the module
toward the opposite direction of the tabs attached side, and remove the LCD
Module from the Housing Panel Assy.
Panel Board
Hooked Tabs
Buttons Buttons
C.B.P 2x6 (4-6kgf.cm)
LCD Module
1 2
Hooked Tabs
Tighten the screws to secure the LCD Module in the order
shown in Figure 2-9.
Make sure the four positioning holes of the Panel Board are
aligned with the two screw holes and put onto the two guide
pins.
Figure 2-10. Reinstalling the Panel Board
Tighten the screws to secure the Panel Shield Plate in the order
shown in Figure 2-8.
Make sure that the Cosmetic Panel is properly fitted on the
Panel Board Assy.
Positioning Holes