Troubleshooting Troubleshooting When There is Error Display 29
DC error
(PF motor)
FBH PF acceleration lock error
An error occurred in the PF
motor operating sequence
Checking the PF mechanism by visual inspection:
Check the PF mechanism for paper jam or adhesion of foreign matters by visual
inspection.
Checking the operation of the PF mechanism:
Operate the PF mechanism by hand, and check to see if it operates smoothly.
Making the following adjustments:
Bi-D
Paper feed length with PF Assy
Paper feed length with Eject Assy
PW adjustment
Checking the following parts and replace the defective one:
Checking the PF Encoder FFC (CN8) for disconnection or breakage
Checking the lead wires of the PF Motor (CN4)for disconnection or breakage
Checking the PF scale for adhesion of dirt or damage (p.61)
Checking the PF encoder for adhesion of dirt or damage (p.61)
Checking the Upper Paper Guides for improper installation (p.69)
Checking the PF Motor and replacing it if necessary (p.61)
Main Board (p.46)
Power Supply Board (p.54)
FEH PF speed over error
FAH
Measurement value error in PF Duty
limiting control
EFH Position error in PF BS control
F0H DTY_max error in PF BS control
F2H PF PID drive time-out judgment error
F3H PF BS drive time-out judgment error
APG motor
70H APG error (normal drive error)
An error occurred in the APG
operating sequence
Checking the installation of the APG Sensor: position of the sensor and connection of
the connector (CN9)
Checking the drive of the APG Assy
Installation of the composite gear of the ASF Assy ~APG Assy
Standalone operation of the APG Assy
Reinstallation of the APG Assy (phase)
Checking the following parts and replace the defective one:
APG Assy (p.64)
ASF Assy (p.63)
APG Sensor
PG Left Cam (p.67)
Main Board (p.46)
Power Supply Board (p.54)
71H APG home seek error
72H Error in APG drive by factory command
Motor drive
time error
D1H
CR (PID) drive time-out
The motor kept operating for
more than the specified time.
Checking the mechanism and operation
Check the mechanism and operation of the motor in question.
Checking the connection of the connectors and routing of the lead wires
Checking the motor in question and the following parts and replacing the defective part
Main Board (p.46)
Power Supply Board (p.54)
D2H
CR (load positioning) drive time-out
D3H
PF (PID) drive time-out
D4H
PF (BS) drive time-out
Factory
command
error
30H
Error by EEPROM verify command
Checking the following parts and replace the defective one:
Main Board (p.46)
Power Supply Board (p.54)
Table 3-3. Fatal Errors (continued)
Category Error Code Error Cause Remedy