Checking the system
21
LEDs on base station
LED1: Green power LED (on when powered)
LED2: Three colour LED, see table 2.
Status of LED2 Meaning Required action
Off Base station operational and no
cordless phone is using the base
station
None
Green Base station operational and a
cordless phone is using the base
station
None
Red Base station is malfunctioning. Try resetting the base station:
By switching the radio
exchange off, waiting half a
minute and switching it on
again.
With CSM (if available).
If the problem persists, please
contact your supplier.
Amber
(yellow-brown)
Base station is OK, but not avail-
able (self-test, not initialized, no
communication with radio
exchange)
Flashing green 8 cordless phones are currently
using the base station: the maxi-
mum capacity of the base station
has been reached
None
If this frequently happens while
users having problems setting up
a call, there may be not enough
base stations. Please contact
your supplier.