Diversity Supervision
36.4 Operational Conditions
The diversity supervision is characterised by a number of parameters
which are implemented as software constants. The parameter values are
selected so that the risk of false disturbances during normal operation is
negligible:
Table 153 Preliminary diversity supervision parameters
Observation period
5 minutes
Channel utilisation threshold -96 dBm
Minimum channel utilisation ratio 5%
Disturbance threshold 12 dB
The disturbance filter characteristics will give the time to alarm. If
100% of the observation periods causes a disturbance, the time to alarm
will be 50 minutes. If the disturbance ratio is less than 50% no alarm
will be raised.
If 100% of the observation periods indicates no disturbance, the alarm
will be terminated after 100 minutes. If the disturbance ratio is more
than 15%, the alarm will not be terminated.