9 Dealing with faults Page 20
Flow chart P-serie BCU
Error 2+5
“false light”
darken burner
chamber
230V to:
Ignition transformer
(audible visible)
pump doesn’t turn
(no oil flow/ fan turns
lightly)
a) Tension too low
b) pump runs heavy
c) Capacitor engine defect
a) pump ceased
pump coupling broken
Oil valve doesn’t open
(no “click”, no oil spray
at outlet)
a) cable oil valve loose
b) coil valve defect
c) oil valve defect
a) pump pressure too high/low
b) oil return line kinked
c) air openings (4) dirty
d) burner head dirty
e) old, worn defect nozzle
f) Oxygen depletion
g) object in 60° spray angle
Burns only 5 seconds (LED 4)
(no photocell current)
a) flame too small
Oxygen depletion
b) photocell (tube) dirty
c) cable photocell loose
d) photocell defect
a) ignites at the wrong spot
b) ignition cable loose
c) electrode torn/cracked
d) Fuse F2 (3,15A) in BCU defect
e) cable ign. transformer loose
f) ign. transformer defect
Heater doesn’t burn
(no flame at all)
a) (manual) oil valve closed
b) oil filter dirty/clogged
c) oil pressure too low
d) insufficient ignition
e) air in the oil lines
f) Oxygen depletion
g) nozzle dirty
h) Water in the oil lines
a) thermal fuse activated
>push reset button on engine
b) fuse F1 (8A) defect
c) engine cable loose
d) engine capacitor defect
e) ventilator blocked
f) motor defect